6 BASIC INSTRUCTIONS
6.6 Data Conversion Instructions
449
6
Processing details
• These instructions convert the hexadecimal ASCII data stored in the device specified by (s) and later to 32-bit binary data,
and store the converted data in the device specified by (d).
• The setting method of the hexadecimal ASCII data to be set in (s) depends on the status of SM705 (Number of conversion
digits selection).
*1 For the firmware version of the CPU module supporting SM705, refer to the following.
MELSEC iQ-R CPU Module User's Manual (Application)
A CPU module which does not support SM705 operates in the same way as SM705 is off even if it is turned on.
■
Setting method of (s) for when SM705 (Number of conversion digits selection) is off
• Set hexadecimal ASCII data with 8 digits (fixed) in (s) to (s)+3.
• The ASCII data in the device specified by (s) to (s)+3 is within the range from 00000000H to FFFFFFFFH.
• The data of (s)+4 or later is ignored.
• A value from 30H to 39H and 41H to 46H can be set in each place of ASCII code.
Ex.
When 5CB807E1H is specified in (s)
Status of SM705
Setting method of (s)
Reference
OFF
Set (s) with a fixed number of digits (8 digits).
Page 449 Setting method of (s) for when SM705 (Number of conversion
digits selection) is off
ON
Set (s) with a desired number of digits (maximum: 8
digits).
Page 450 Setting method of (s) for when SM705 (Number of conversion
digits selection) is on
ASCII
: ASCII code (
th digit)
(1) Upper 16 bits
(2) Lower 16 bits
(s)
(s)+1
(s)+2
(s)+3
b15
b0
∙∙∙
∙∙∙
b7
b8
b0
∙∙∙
∙∙∙
b31
b16 b15
(d)+1
(d)
ASCII 7
ASCII 5
ASCII 3
ASCII 8
ASCII 6
ASCII 4
ASCII 1
ASCII 2
BIN32
(1)
(2)
(s)
(s)+1
(s)+2
(s)+3
b15
b0
∙∙∙
∙∙∙
b7
b8
b0
∙∙∙
∙∙∙
b31
b16 b15
(d)+1
(d)
43H (C)
38H (8)
37H (7)
35H (5)
42H (B)
30H (0)
31H (1)
45H (E)
5CB8H
07E1H
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......