7 APPLICATION INSTRUCTIONS
7.9 Real Number Instructions
715
7
Outputting a band comparison result of double-precision real
number
EDZCP(P)
These instructions compare the band between the double-precision real number specified by lower limit value (s1) and the
double-precision real number specified by upper limit value (s2) with the double-precision real number in the device specified
by comparison data (s3). According to the comparison result (below, within zone, or above), (d), (d)+1, or (d)+2 is turned on.
■
Execution condition
Setting data
■
Description, range, data type
• The RnCPU and RnENCPU with firmware version "17" or later support these instructions. (Use an engineering tool with version "1.020W" or later.)
Ladder
ST
ENO:= EDZCP(EN, s1, s2, s3, d);
ENO:= EDZCPP(EN, s1, s2, s3, d);
FBD/LD
Instruction
Execution condition
EDZCP
EDZCPP
Operand
Description
Range
Data type
Data type (label)
(s1)
Lower limit value or the start device for storing the lower
limit value
0, 2
-1022
|(s1)|<2
1024
Double-precision real
number
ANYREAL_64
(s2)
Upper limit value or the start device for storing the upper
limit value
0, 2
-1022
|(s2)|<2
1024
Double-precision real
number
ANYREAL_64
(s3)
Comparison data or the start device for storing the
comparison data
0, 2
-1022
|(s3)|<2
1024
Double-precision real
number
ANYREAL_64
(d)
The start device where the comparison result is stored
Bit
ANYBIT_ARRAY
(Number of elements: 3)
EN
Execution condition
Bit
BOOL
ENO
Execution result
Bit
BOOL
RnCPU RnENCPU
RnSFCPU RnSFCPU
RnPCPU
RnPCPU
(Standard)
(Safety)
(Redundant)
(Process)
(s1)
(s2)
(s3)
(d)
EN
ENO
d
s1
s2
s3
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......