18 CC-LINK IE FIELD NETWORK INSTRUCTIONS
18.3 Reading Data from the Intelligent Device Station/Remote Device Station (32-bit Address Specified)
1611
18
Setting data
■
Description, range, data type
*1 A channel is used only for the REMFR, REMTO, REMFRD, and REMTOD instructions.
The same channel number used for the link dedicated instructions (such as the READ instruction) can be set.
*2 This is the start I/O number (first three digits in four-digit hexadecimal representation) of intelligent function modules.
*3 When specifying setting data by using a label, define an array to secure enough operation area and specify an element of the array
label.
*4 When a station in a redundant system is targeted, specify the station number in the control system by using the module FB
(RedundantSystem_GetAddress).
MELSEC iQ-R Ethernet/CC-Link IE Function Block Reference
■
Applicable devices
*1 FX and FY cannot be used.
*2 FD cannot be used.
*3 T, ST, C, and FD cannot be used.
Operand
Description
Range
Data type
Data type (label)
(J)
Target network number
1 to 239
16-bit unsigned binary
ANY16
(s1)
Channel of the own station, which is used for the
instruction
1 to 32
16-bit unsigned binary
ANY16
(s2)
Target station number
1 to 120
16-bit unsigned binary
ANY16
(s3)
Start I/O number of target station
■
Head module:
00H to FEH
■
Modules other than the head
module:
00H (fixed)
16-bit unsigned binary
ANY16
(s4)
Start address of the buffer memory area of the
intelligent device station or the remote device station
where the read-target data is stored
0000H to FFFFFFFFH (0 to
4294967295)
32-bit unsigned binary
ANY32
(d1)
Start device of the own station for storing the read
data
Device name
ANY16
(n)
Number of read data points (in units of words)
1 to 240
16-bit unsigned binary
ANY16
(d2)
Device of the own station, which turns on for one
scan upon completion of the instruction.
When the instruction completes with an error, (d2)+1
also turns on.
Bit
ANYBIT_ARRAY
(Number of elements:
2)
EN
Execution condition
Bit
BOOL
ENO
Execution result
Bit
BOOL
Operand
Bit
Word
Double word Indirect
specification
Constant
Others
(J)
X, Y, M, L,
SM, F, B, SB,
FX, FY
J
\
T, ST, C, D, W,
SD, SW, FD, R,
ZR, RD
U
\G
, J
\
,
U3E
\(H)G
Z
LT, LST,
LC
LZ
K, H E $
(J)
(s1)
(s2)
(s3)
(s4)
(d1)
(n)
(d2)
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......