APPX
Appendix 1 Instruction Processing Time
2013
A
MIDW
4.200
12.300
INSTR
No match
7.500
15.000
Match: Start
5.300
13.000
Match: Last
7.500
15.300
STRINS
(s)=128, (d)=40, (n)=1
17.900
27.200
(s)=128, (d)=40, (n)=48
20.400
30.100
STRDEL
(s)=128, (d)=40, (n)=1
15.800
23.000
(s)=128, (d)=40, (n)=48
13.600
20.900
LDE=
Continuity/Non-continuity
0.00588
LDE<>
Continuity/Non-continuity
0.00588
LDE>
Continuity/Non-continuity
0.00588
LDE<=
Continuity/Non-continuity
0.00588
LDE<
Continuity/Non-continuity
0.00588
LDE>=
Continuity/Non-continuity
0.00588
ANDE=
When not executed
0.00588
When executed: continuity/non-continuity
0.00588
ANDE<>
When not executed
0.00588
When executed: continuity/non-continuity
0.00588
ANDE>
When not executed
0.00588
When executed: continuity/non-continuity
0.00588
ANDE<=
When not executed
0.00588
When executed: continuity/non-continuity
0.00588
ANDE<
When not executed
0.00588
When executed: continuity/non-continuity
0.00588
ANDE>=
When not executed
0.00588
When executed: continuity/non-continuity
0.00588
ORE=
When not executed
0.00588
When executed: continuity/non-continuity
0.00588
ORE<>
When not executed
0.00588
When executed: continuity/non-continuity
0.00588
ORE>
When not executed
0.00588
When executed: continuity/non-continuity
0.00588
ORE<=
When not executed
0.00588
When executed: continuity/non-continuity
0.00588
ORE<
When not executed
0.00588
When executed: continuity/non-continuity
0.00588
ORE>=
When not executed
0.00588
When executed: continuity/non-continuity
0.00588
LDED=
Continuity/Non-continuity
1.900
4.500
LDED<>
Continuity/Non-continuity
1.900
4.500
LDED>
Continuity/Non-continuity
1.800
4.400
LDED<=
Continuity/Non-continuity
1.900
4.500
LDED<
Continuity/Non-continuity
1.900
4.500
LDED>=
Continuity/Non-continuity
1.900
4.500
ANDED=
When not executed
0.00588
When executed: continuity/non-continuity
1.900
4.500
ANDED<>
When not executed
0.00588
When executed: continuity/non-continuity
1.900
4.500
ANDED>
When not executed
0.00588
When executed: continuity/non-continuity
1.900
4.500
ANDED<=
When not executed
0.00588
When executed: continuity/non-continuity
1.900
4.500
Instruction name
Condition
Processing time (
s)
Minimum
Maximum
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......