2022
APPX
Appendix 1 Instruction Processing Time
LDTM<=
When compared with the specified time: Continuity
2.600
9.200
When compared with the specified time: Non-continuity
2.700
9.200
When compared with the current time: Continuity
4.900
14.500
When compared with the current time: Non-continuity
4.900
14.600
LDTM<
When compared with the specified time: Continuity
2.600
9.300
When compared with the specified time: Non-continuity
2.600
9.300
When compared with the current time: Continuity
4.700
14.800
When compared with the current time: Non-continuity
4.900
14.700
LDTM>=
When compared with the specified time: Continuity
2.500
9.100
When compared with the specified time: Non-continuity
2.600
9.200
When compared with the current time: Continuity
4.900
14.500
When compared with the current time: Non-continuity
4.800
14.600
ANDTM=
When not executed
0.00588
When compared with the specified time: Continuity
2.400
9.100
When compared with the specified time: Non-continuity
2.500
9.200
When compared with the current time: Continuity
4.900
14.600
When compared with the current time: Non-continuity
4.900
14.700
ANDTM<>
When not executed
0.00588
When compared with the specified time: Continuity
2.400
9.100
When compared with the specified time: Non-continuity
2.600
9.400
When compared with the current time: Continuity
4.900
14.800
When compared with the current time: Non-continuity
4.900
14.800
ANDTM>
When not executed
0.00588
When compared with the specified time: Continuity
2.600
9.400
When compared with the specified time: Non-continuity
2.600
9.500
When compared with the current time: Continuity
4.800
14.700
When compared with the current time: Non-continuity
4.900
14.800
ANDTM<=
When not executed
0.00588
When compared with the specified time: Continuity
2.600
9.400
When compared with the specified time: Non-continuity
2.600
9.400
When compared with the current time: Continuity
4.900
15.000
When compared with the current time: Non-continuity
4.900
14.900
ANDTM<
When not executed
0.00588
When compared with the specified time: Continuity
2.600
9.500
When compared with the specified time: Non-continuity
2.600
9.600
When compared with the current time: Continuity
4.900
14.700
When compared with the current time: Non-continuity
4.900
14.800
ANDTM>=
When not executed
0.00588
When compared with the specified time: Continuity
2.600
9.400
When compared with the specified time: Non-continuity
2.600
9.400
When compared with the current time: Continuity
4.900
14.900
When compared with the current time: Non-continuity
4.800
14.900
ORTM=
When not executed
0.00588
When compared with the specified time: Continuity
2.700
9.200
When compared with the specified time: Non-continuity
2.700
9.100
When compared with the current time: Continuity
5.000
14.900
When compared with the current time: Non-continuity
5.000
14.800
ORTM<>
When not executed
0.00588
When compared with the specified time: Continuity
2.700
9.200
When compared with the specified time: Non-continuity
2.700
9.200
When compared with the current time: Continuity
5.000
15.000
When compared with the current time: Non-continuity
5.000
15.000
Instruction name
Condition
Processing time (
s)
Minimum
Maximum
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...