2 CPU MODULE INSTRUCTIONS
2.3 Application Instructions
■
Hour meter
Module access instructions
■
Performing I/O refresh
■
Selecting refresh to be performed
■
Performing module refresh
■
Reading 1-word/2-word data from another module (16-bit specification)
■
Writing 1-word/2-word data to a module (16-bit specification)
■
Reading 1-word/2-word data from another module (32-bit specification)
■
Writing 1-word/2-word data to a module (32-bit specification)
Instruction symbol
Processing details
Reference
HOURM
Measures the period of time for which the start contact is ON in units of hour, and turns on the
device specified by (d2) when the accumulated ON time reaches the time (16-bit binary data)
specified in (s).
DHOURM
Measures the period of time for which the start contact is ON in units of hour, and turns on the
device specified by (d2) when the accumulated ON time reaches the time (32-bit binary data)
specified in (s).
Instruction symbol
Processing details
Reference
RFS
Performs partial refresh of the relevant input/output during one scan.
RFSP
Instruction symbol
Processing details
Reference
COM
Performs refresh and service processing for various modules when the input condition is met.
COMP
Instruction symbol
Processing details
Reference
S.ZCOM
Performs refresh processing for the specified modules.
SP.ZCOM
Instruction symbol
Processing details
Reference
FROM
Reads (n) words of data in units of 16 bits from the buffer memory areas of the intelligent function
module and other CPU modules.
FROMP
DFROM
Reads (n)
2 words of data in units of 16 bits from the buffer memory areas of the intelligent
function module and other CPU modules.
DFROMP
Instruction symbol
Processing details
Reference
TO
Writes (n) words of data in units of 16 bits to the buffer memory areas of the intelligent function
module and own CPU module.
TOP
DTO
Writes (n)
2 words of data in units of 16 bits to the buffer memory areas of the intelligent function
module and own CPU module.
DTOP
Instruction symbol
Processing details
Reference
FROMD
Reads (n) words of data in units of 32 bits from the buffer memory areas of the intelligent function
module and other CPU modules.
FROMDP
DFROMD
Reads (n)
2 words of data in units of 32 bits from the buffer memory areas of the intelligent
function module and other CPU modules.
DFROMDP
Instruction symbol
Processing details
Reference
TOD
Writes (n) words of data in units of 32 bits to the buffer memory areas of the intelligent function
module and own CPU module.
TODP
DTOD
Writes (n)
2 words of data in units of 32 bits to the buffer memory areas of the intelligent function
module and own CPU module.
DTODP
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......