6 BASIC INSTRUCTIONS
6.4 Bit Processing Instructions
349
6
Processing details
• These instructions reset the (n) points of bit devices starting from the bit device specified by (d).
• The following table lists the reset status of the bit devices.
• When the specified device is off, the device status does not change.
Operation error
There is no operation error.
Device
Status
Annunciator (F)
• The (n) points of data starting from the annunciator (F) number in the device specified by (d) turn off.
• The annunciator numbers that turned off are deleted from SD64 to SD79, and the remaining data are
compressed forward.
• The number of annunciators stored in SD64 to SD79 is stored in SD63.
Timer (T), retentive timer (ST), counter
(C), long timer (LT), long retentive timer
(LST), long counter (LC)
• The (n) points, starting from the timer (T), retentive timer (ST), counter (C), long timer (LT), long retentive timer
(LST), or long counter (LC) number in the device specified by (d), of current values are reset to 0, and the (n)
points of coils and contacts are turned off.
Bit devices other than the above
• The (n) points, starting from the device specified by (d), of coils and contacts are turned off.
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......