6 BASIC INSTRUCTIONS
6.6 Data Conversion Instructions
Operation error
*1 When SM705 (Number of conversion digits selection) is off, no error is detected no matter what value is set for the ASCII code of the
first character.
Error code
(SD0)
Description
3401H
Invalid data that cannot be converted are input in (s) to (s)+5.
• The ASCII code of the first character is other than 2DH, 30H to 39H, 20H, and 00H.
• The ASCII code of the second character or later is other than 30H to 39H, 20H, and 00H.
• When the DDABIN(P) instruction is used, ASCII data is out of the range from -2147483648 to 2147483647.
• When the DDABIN(P)_U instruction is used, ASCII data is out of the range from 0 to 4294967295.