1872
25 TYPE CONVERSION FUNCTIONS
25.57 Converting STRING to DINT
25.57
Converting STRING to DINT
STRING_TO_DINT(_E)
These functions convert a value from STRING data type to DINT data type.
Setting data
■
Description, type, data type
Processing details
■
Operation processing
• These functions convert the value input to (s) from STRING data type to DINT data type, and output the converted value
from (d).
• Input a STRING data type value to (s) within the following range.
■
Operation result
1.
Function without EN/ENO
The operation processing is performed. The operation result is output from (d).
2.
Function with EN/ENO
The execution conditions and operation results will be as follows.
*1 If the value FALSE is output from ENO, the output data from (d) will be undefined. Create a program so that the undefined value will not
be used in operations.
Ladder, FBD/LD
Structured text
[Without EN/ENO]
[With EN/ENO]
[Without EN/ENO]
d:=STRING_TO_DINT(s);
[With EN/ENO]
d:=STRING_TO_DINT_E(EN,ENO,s);
Argument
Description
Type
Data type
EN
Execution condition (TRUE: Executed, FALSE: Not executed)
Input variable
BOOL
s (IN)
Input
Input variable
STRING(11)
ENO
Output status (TRUE: Normal, FALSE: Abnormal)
Output variable
BOOL
d
Output
Output variable
DINT
• ASCII code: 30H to 39H, 20H, 2DH, and 00H
• STRING data type value: -2147483648 to 2147483647
Execution condition
Operation result
EN
ENO
(d)
TRUE (executed)
TRUE
Operation result output value
FALSE (not executed)
FALSE
Undefined value
RnCPU RnENCPU
RnSFCPU RnSFCPU
RnPCPU
RnPCPU
(Standard)
(Safety)
(Redundant)
(Process)
s
d
EN
ENO
d
s
(s)
(d)
+0
+5
+4
+3
+2
+1
STRING
DINT
Lower byte
Upper byte
ASCII code (sign data)
ASCII code (billions place)
ASCII code (ones place)
ASCII code (hundreds place)
00H (Null character (end of string))
ASCII code (tens place)
ASCII code (ten-thousands place)
ASCII code (thousands place)
ASCII code (millions place)
ASCII code (hundred-thousands place)
ASCII code (hundred-millions place)
ASCII code (ten-millions place)
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......