8 BUILT-IN ETHERNET FUNCTION INSTRUCTIONS
8.4 SLMP Frame Send Instruction
1119
8
*1 If (s1)+0 is set to "0: Without arrival check", receive data is not set. Set 0 in (s1)+0 in the following cases:
When a command that does not return a response message is used
When a response message is not referred to
*2 Give the serial numbers when sending several request messages to the same SLMP-compatible device. Serial numbers to be given are
automatically numbered by the system. For the serial number, refer to the following.
SLMP Reference Manual
■
Request frame
+9
Request destination
multidrop station
number
0000H (fixed)
0000H
User
+10
Number of resends
The device becomes effective when the execution type specified by (s1)+0 is "1: With
arrival check".
■
Before instruction execution
Specify the number of resends to be performed if the instruction is not completed
within the monitoring time specified by (s1)+11.
• 0 to 15 (times)
■
At completion of instruction
The number of resends performed (result) is stored.
• 0 to 15 (times)
0 to 15
User/
system
+11
Arrival monitoring time
Specify the monitoring time until completion of processing. If processing is not
completed within the monitoring time, the request is resent the number of times
specified in (s1)+10.
• 0: 10s
• 1 to 32767: 1 to 32767s
0 to 32767
User
+12
Clock setting flag
The validity status (valid or invalid) of the data in (s)+13 and later is stored. Note that
the data in (s1)+13 and later is cleared when the instruction is completed
successfully.
• 0: Invalid
• 1: Valid
System
+13
Clock data
Upper 8 bits: Month (01H to 12H)
Lower 8 bits: Year (00H to 99H: Lower two digits of the year)
System
+14
Upper 8 bits: Hour (00H to 23H)
Lower 8 bits: Day (01H to 31H)
+15
Upper 8 bits: Second (00H to 59H)
Lower 8 bits: Minute (00H to 59H)
+16
Upper 8 bits: Year (00H to 99H: Upper two digits of the year)
Lower 8 bits: Day of the week (00H (Sun.) to 06H (Sat.))
+17
IP address of error
detected device (third
and fourth octets)
The IP address (third and fourth octets) of the station where an error was detected is
stored.
3, 4: Indicates the octets of the IP address.
System
+18
IP address of error
detected device (first
and second octets)
The IP address (first and second octets) of the station where an error was detected is
stored.
1, 2: Indicates the octets of the IP address.
System
Operand: (s2)
Device
Item
Description
Setting range
Set by
+0
Request data length
Specify the data length from the monitoring timer to the request data. (In units of
bytes)
1 to 2000
User
+1
Monitoring timer
This timer sets the waiting time for the external device that received a request
message to wait for the response after it issued a processing request to the access
destination. (Unit: Increments of 250ms)
• 0: Infinite wait
• 1 to 65535: 1 to 65535
250ms
0 to 65535
User
+2 to +
Request data
The request data of the SLMP message is stored.
User
Operand: (s1)
Device
Item
Description
Setting range
Set by
b15
b7
b8
b0
3
4
b15
b7
b8
b0
1
2
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......