APPX
Appendix 1 Instruction Processing Time
2017
A
SCL2
SM755=ON, point No.1<(s1)<point No.2
3.300
9.200
SM755=ON, point No.9<(s1)<point No.10
3.300
9.100
SM755=OFF, point No.1<(s1)<point No.2
3.300
8.700
SM755=OFF, point No.9<(s1)<point No.10
3.500
8.800
SCL2_U
SM755=ON, point No.1<(s1)<point No.2
3.200
8.800
SM755=ON, point No.9<(s1)<point No.10
3.300
8.900
SM755=OFF, point No.1<(s1)<point No.2
2.900
8.500
SM755=OFF, point No.9<(s1)<point No.10
3.500
9.000
DSCL2
SM755=ON, point No.1<(s1)<point No.2
3.300
10.000
SM755=ON, point No.9<(s1)<point No.10
3.300
10.000
SM755=OFF, point No.1<(s1)<point No.2
3.000
9.500
SM755=OFF, point No.9<(s1)<point No.10
3.300
10.100
DSCL2_U
SM755=ON, point No.1<(s1)<point No.2
3.200
10.100
SM755=ON, point No.9<(s1)<point No.10
3.300
10.100
SM755=OFF, point No.1<(s1)<point No.2
2.900
9.600
SM755=OFF, point No.9<(s1)<point No.10
3.500
10.000
UDCNT1
0.800
1.600
UDCNT2
0.800
1.600
TTMR
2.000
5.900
STMR
2.700
8.100
ROTC
4.800
8.600
RAMPQ
3.400
8.200
SPD
0.700
1.600
PLSY
0.800
1.400
PWM
0.800
1.400
MTR
3.400
11.600
CCD
SM772=OFF, (n)=1
3.300
7.100
SM772=OFF, (n)=96
11.700
15.500
SM772=ON, (n)=1
3.300
7.100
SM772=ON, (n)=96
11.700
15.500
SERDATA
(n)=1: All match
2.700
6.700
(n)=1: All mismatch
2.700
6.600
(n)=96: All match
9.700
15.000
(n)=96: All mismatch
9.700
15.100
DSERDATA
(n)=1: All match
3.000
7.300
(n)=1: All mismatch
3.000
7.300
(n)=96: All match
14.500
18.900
(n)=96: All mismatch
14.500
18.900
SERMM
(n)=1, no matched data
4.100
9.300
(n)=1, number of the matched data = 1
4.100
9.300
(n)=96, no matched data
13.100
18.200
(n)=96, number of the matched data = 96
13.100
18.200
DSERMM
(n)=1, no matched data
4.100
9.300
(n)=1, number of the matched data = 1
4.100
9.300
(n)=96, no matched data
13.100
18.200
(n)=96, number of the matched data = 96
13.100
18.200
SUM
(s)=0
1.300
1.900
(s)=FFFFH
1.300
1.900
DSUM
(s)=0
1.700
2.400
(s)=FFFFFFFFH
1.700
2.400
BON
(s)=0
2.400
4.900
(s)=FFFFH
2.400
4.900
Instruction name
Condition
Processing time (
s)
Minimum
Maximum
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......