19 CC-LINK INSTRUCTIONS
19.3 Reading Data from the Buffer Memory of the Specified Intelligent Device Station
■
Applicable devices
*1 Index modification is not available.
*2 FX and FY cannot be used.
*3 FD cannot be used.
*4 T, ST, C, and FD cannot be used.
■
Control data
*1 Specify a value within the capacity of the target station buffer memory area.
■
Interlock signal
*1 For the interlock signal, refer to the following.
Manual of the intelligent device station from which to read data
Operand
Bit
Word
Double word Indirect
specification
Constant
Others
(U)
X, Y, M, L,
SM, F, B, SB,
FX, FY
J
\
T, ST, C, D, W,
SD, SW, FD, R,
ZR, RD
U
\G
, J
\
,
U3E
\(H)G
Z
LT, LST,
LC
LZ
K, H E
$
(U)
(s1)
(d1)
(s2)
(d2)
Operand: (s1)
Device
Item
Description
Setting range
Set by
+0
Completion status
The completion status is stored upon completion of the instruction.
• 0: Completed successfully
• Other than 0: Completed with an error (error code)
System
+1
Station number
Specify the station number of the target station.
1 to 64
User
+2
Access/attribute code
Specifies 0004H.
0004H
User
+3
Buffer memory address
Specifies the start address of the buffer memory area from which to read data.
Refer to the
manual of the
target station.
User
+4
Number of read points
Specifies, in units of words, the number of points to be read.
1 to 480
User
Operand: (s2)
Device
Item
Description
Setting
range
Set by
+0
RY: Specifies the number of the completion signal (RY) to be used for
interlock.
00H to 7FH
User
+1
RY: Specifies the number of the read request signal (RY) to be used for
interlock.
00H to 7FH
User
+2
Dummy
Specifies 0.
0
User
0
RY
b15
b8 b7
b0
…
…
0
RX
b15
b8 b7
b0
…
…
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......