6 BASIC INSTRUCTIONS
6.6 Data Conversion Instructions
429
6
Processing details
• These instructions convert the 32-bit binary data in the device specified by (s) to 32-bit binary Gray code data, and store the
converted data in the device specified by (d).
Operation error
(s)+1: Upper 16 bits
(s): Lower 16 bits
Error code
(SD0)
Description
3401H
When the DGRY(P) instruction is used, the value in the device specified by (s) is out of the range, 0 to 2147483647.
(s) BIN
(d)
0
305419896 0
0 1 0 0 1 0 0 0 1 1 0 1 0 0 0 1 0 1 0 1 1 0 0 1 1 1 1 0 0 0
b31
b16
b0
b15
0
305419896 0
0 1 1 0 1 1 0 0 1 0 1 1 1 0 0 1 1 1 1 1 0 1 0 1 0 0 0 1 0 0
(d)+1
b31
b16
b0
b15
(d)
∙∙∙
∙∙∙
∙∙∙
∙∙∙
(s)+1
(s)