1912
27 ARITHMETIC OPERATION FUNCTIONS
27.4 Division
27.4
Division
DIV(_E)
These functions output the quotient of input values ((s1)
(s2)).
Setting data
■
Description, type, data type
Processing details
■
Operation processing
• These functions perform division between the INT, DINT, REAL, or LREAL data type values input to (s1) and (s2)
((s1)
(s2)), and output the operation result, in the same data type as (s), from (d).
Ex.
Data type: INT
• Input an INT, DINT, REAL, or LREAL data type value to (s1) and (s2). provided that the value input to (s2) shall be other
than 0.
■
Operation result
1.
Function without EN/ENO
The operation processing is performed. The operation result is output from (d).
2.
Function with EN/ENO
The execution conditions and operation results will be as follows.
*1 If the value FALSE is output from ENO, the output data from (d) will be undefined. Create a program so that the undefined value will not
be used in operations.
Ladder, FBD/LD
Structured text
[Without EN/ENO]
[With EN/ENO]
[Without EN/ENO]
d:=DIV(s1,s2);
[With EN/ENO]
d:=DIV_E(EN,ENO,s1,s2);
Argument
Description
Type
Data type
EN
Execution condition (TRUE: Executed, FALSE: Not executed)
Input variable
BOOL
s1 (IN1)
Dividend
Input variable
ANY_NUM
s2 (IN2)
Divisor
Input variable
ANY_NUM
ENO
Output status (TRUE: Normal, FALSE: Abnormal)
Output variable
BOOL
d
Output
Output variable
ANY_NUM
Execution condition
Operation result
EN
ENO
(d)
TRUE (executed)
TRUE
Operation result output value
FALSE (not executed)
FALSE
Undefined value
RnCPU RnENCPU
RnSFCPU RnSFCPU
RnPCPU
RnPCPU
(Standard)
(Safety)
(Redundant)
(Process)
s1
d
s2
EN
ENO
d
s1
s2
(s1)
(s2)
(d)
1
2
2
÷
5
INT
INT
INT
Remainder
Quotient
The value is not output.
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......