6 BASIC INSTRUCTIONS
6.2 Arithmetic Operation Instructions
■
Applicable devices
• In safety programs executed by the Safety CPU, only the following safety devices and constants can be used.
Processing details
• These instructions divide the 16-bit binary data in the device specified by (s1) by the 16-bit binary data in the device
specified by (s2), and store the operation result in the device specified by (d).
• As the operation result, the quotient and remainder are stored in 32 bits. When a bit device is specified, the number of digit-
specified bits is used to store the quotient and remainder.
Operation error
Operand
Bit
Word
Double word Indirect
specification
Constant
Others
X, Y, M, L,
SM, F, B, SB,
FX, FY
J
\
T, ST, C, D, W,
SD, SW, FD, R,
ZR, RD
U
\G
, J
\
,
U3E
\(H)G
Z
LT, LST,
LC
LZ
K,
H
E
$
(s1)
(s2)
(d)
Operand
Bit
Word
Constant
SA\X, SA\Y, SA\M, SA\SM, SA\B
SA\T, SA\ST, SA\C, SA\D, SA\W, SA\SD
K, H
(s1)
(s2)
(d)
(d): Quotient
(d)+1: Remainder
• Quotient
Stored in lower 16 bits.
• Remainder
Stored in upper 16 bits.
Error code
(SD0)
Description
3400H
The value (divisor) in the device specified by (s2) is 0.
b15
b0
5678 (BIN)
(s1)
(s2)
1234 (BIN)
4 (BIN)
742 (BIN)
÷
···
b15
b0
···
(d)
(d)+1
b0
···
···
b15
b0 b15
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......