30 SELECTION FUNCTIONS
30.3 Controlling the Upper/Lower Limit
1937
30
• When (s1), (s2), or (s3) are of BOOL data type
• When (s1), (s2), and (s3) are of REAL data type
• When (s1), (s2), and (s3) are of LREAL data type
• When (s1), (s2), and (s3) are of STRING data type
Error code
(SD0)
Description
3405H
The lower limit value specified by (s1) is greater than the upper limit value specified by (s3).
Error code
(SD0)
Description
3402H
The value input to (s1) is out of the following range:
-2
128
<(s1)
-2
-126
, 0, 2
-126
(s1)<2
128
(E-3.438 to E-1.17549435-38, 0, E1.17549435-38 to E3.438)
The value input to (s1) is -0, a subnormal number, NaN (not a number), or
.
The value input to (s2) is out of the following range:
-2
128
<(s2)
-2
-126
, 0, 2
-126
(s2)<2
128
(E-3.438 to E-1.17549435-38, 0, E1.17549435-38 to E3.438)
The value input to (s2) is -0, a subnormal number, NaN (not a number), or
.
The value input to (s3) is out of the following range:
-2
128
<(s3)
-2
-126
, 0, 2
-126
(s3)<2
128
(E-3.438 to E-1.17549435-38, 0, E1.17549435-38 to E3.438)
The value input to (s3) is -0, a subnormal number, NaN (not a number), or
.
3405H
The lower limit value specified by (s1) is greater than the upper limit value specified by (s3).
Error code
(SD0)
Description
3402H
The value input to (s1) is out of the following range:
-2
1024
<(s1)
-2
-1022
, 0, 2
-1022
(s1)<2
1024
(E-1.797693134308 to E-2.2250738585072014-308, 0, E2.2250738585072014-308 to E1.797693134308)
The value input to (s1) is -0, a subnormal number, NaN (not a number), or
.
The value input to (s2) is out of the following range:
-2
1024
<(s2)
-2
-1022
, 0, 2
-1022
(s2)<2
1024
(E-1.797693134308 to E-2.2250738585072014-308, 0, E2.2250738585072014-308 to E1.797693134308)
The value input to (s2) is -0, a subnormal number, NaN (not a number), or
.
The value input to (s3) is out of the following range:
-2
1024
<(s3)
-2
-1022
, 0, 2
-1022
(s3)<2
1024
(E-1.797693134308 to E-2.2250738585072014-308, 0, E2.2250738585072014-308 to E1.797693134308)
The value input to (s3) is -0, a subnormal number, NaN (not a number), or
.
3405H
The lower limit value specified by (s1) is greater than the upper limit value specified by (s3).
Error code
(SD0)
Description
2820H
There is no NULL code (00H) in the label or device area (between the specified device number and the last device number) specified by
(s1), (s2), or (s3).
3405H
The lower limit value specified by (s1) is greater than the upper limit value specified by (s3).
The number of characters in the strings input to (s1), (s2), and (s3) exceeds 16383.
3406H
The entire string cannot be stored in the label or device area (between the specified device number and the last device number) specified
by (d). (The number of required points is insufficient.)
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......