background image

 

 www.vega-absolute.ru 

 

 

 

 

 

HUMIDITY/TEMPERATURE/DOOR AND 
WINDOW/ACCELERATION SENSOR 

SMART-HS0101 

User Manual 

 

 

 

 

 

 

 

 

Vega Smart-HS0101 sensor combines a several 
functions, namely: door and window sensor, 
accelerometer, which determines the presence of 
vibration and the angle of deviation from the vertical, 
control of temperature and humidity parameters of the 
environment with the ability to set the ranges of these 
parameters. When any of the alarm events occur the 
message with corresponding information sent to 
LoRaWAN™ network. 

 

 

Summary of Contents for SMART-HS0101

Page 1: ...namely door and window sensor accelerometer which determines the presence of vibration and the angle of deviation from the vertical control of temperature and humidity parameters of the environment w...

Page 2: ...nsor Smart HS0101 Document type Manual Translation from Russian Document number V05 HS0101 01 Revision and date 01 01 February 2019 This document applies to the following products Product name Type nu...

Page 3: ...Mounting options 10 Initial startup 11 Connecting via USB 13 4 VEGA LORAWAN CONFIGURATOR 15 Interface of the application 15 Connection to the device 16 Device info tab 17 LoRaWAN settings tab 19 Smar...

Page 4: ...e sensor manufactured by Vega Absolute LLC and provides information on powering and activation procedure control commands and functions of the device This manual is targeted at specialists familiar wi...

Page 5: ...e of four colors versions black brown white and grey The sensor powered by a CR123A 1400 mAh replaceable battery The sensor configuring via USB with special software Vega LoRaWAN Configurator COMUNICA...

Page 6: ...the device memory until the next communication session With the Confirmed uplinks option turned off the device just sends all accumulated packets to the network in order from the earliest to the lates...

Page 7: ...r of manufacture o QR code containing DevEUI for automatized count Sticker located in three places on device case in factory certificate and on the packing box Besides there is an additional sticker l...

Page 8: ...Communication period 5 15 30 minutes 1 6 12 or 24 hours Data collection period 5 15 30 minutes 1 6 12 or 24 hours Memory amount for storing packets 200 packets Antenna internal Sensitivity 138 dBm Ra...

Page 9: ...The device connected to the network and in Active mode One long red flash Linking to the network is unsuccessful or the device switched to the Storage mode One short blue flash Data transmitting in pr...

Page 10: ...two components main part including all of electronics magnet Device contain two Hall sensors located in two different places on a board That allows mounting device in two ways 1 The magnet is located...

Page 11: ...A 3V 1400 mAh replaceable battery You need to insert the battery observing the polarity before start The sensor supports two activation methods in the LoRaWAN network ABP and OTAA Select one of the me...

Page 12: ...ttempts fail the sensor will continue to accumulate data and will attempt to connect to the network every 6 hours To switch the device from the Active mode to the Storage mode you can use the long pre...

Page 13: ...ice to the computer for the first time you must install the driver for the COM port stsw stm32102 which can be downloaded from iotvega com After running the executable file VCP_V1 4 0_Setup exe the in...

Page 14: ...Smart HS0101 User Manual 14 Revision 01 01 February 2019 After pressing Finish the driver is ready for operation it is possible to connect the device via USB...

Page 15: ...f the signal from the gateways are available Next the work of the configurator is considered in the Expert mode INTERFACE OF THE APPLICATION The Vega LoRaWAN Configurator application does not require...

Page 16: ...enu on the left The configurator automatically recognizes the type of device and the device selection menu becomes inactive To read the settings from the device you need to click the Get settings butt...

Page 17: ...isplayed in the Simple mode allows you to change the factory keys to register the device on the network and reset the keys back to the factory settings Device info the configurator reads information a...

Page 18: ...procedure will occurs Link check not displayed in the Simple mode when pressed the device sends a special signal to the LoRaWAN network in response to which the network informs it of the number of gat...

Page 19: ...868 based In the device frequency plan only those channels are active by default on which sending requests for connection to the network join channels The remaining channels that the device should use...

Page 20: ...Activation type selecting ABP or OTAA device activation method Confirmed uplinks when you choose confirmed the device will retry sending the packet until it receives the server confirmation or until...

Page 21: ...e mode specifies the time between end of packet transmission and first receiving window opening The second receiving window always opens after 1 second after the first Join accept delay 1 not displaye...

Page 22: ...packet as many times as specified in this option If Confirmed uplinks is enabled the device will send packets until it receives a confirmation or until it sends as many packets as specified in this o...

Page 23: ...on 01 01 February 2019 TX datarate not displayed in the Simple mode the device transmission datarate at which it will transfer packets to the LoRaWAN network This speed can be change by the network se...

Page 24: ...re the collection and transmission periods and the time zone for the internal clock of the counter will be set which When temperature humidity values come out of range then transmission period remains...

Page 25: ...humidity range set independently and may change from 5 minutes to 24 hours Opening sensors settings allows to setting the alarm message sending option for every Hall sensor exactly by the close or ope...

Page 26: ...this packet for packet type 1 Time of the modem at the moment of the packet transmission for the packets type 2 5 unixtime UTC uint32 2 bytes Temperature in multiplied by 10 int16 1 byte Humidity in u...

Page 27: ...onnected to the network Size in bytes Field description Data type 1 byte Packet type this packet 0 2 bytes ID of parameter uint16 1 byte Data length len uint8 len bytes Parameter value 2 bytes ID of p...

Page 28: ...application on LoRaWAN port 3 Size in bytes Field description 1 byte Packet type this packet 1 Answering that packet the device sent the packet with settings 3 Packet with settings is identical to su...

Page 29: ...message sensor 2 1 byte 1 short close 2 open 3 short and open close and open 4 disabled 44 Accelerometer sensitivity 1 byte 1 low 2 middle 3 high 4 disable 49 Data collection period 1 byte 1 1 hour 2...

Page 30: ...ATION REQUIREMENTS The Smart HS0101 sensor shall be stored in the original packaging in heated room at temperatures 5 to 40 and relative humidity less than 85 The sensor shall be transported in covere...

Page 31: ...Smart HS0101 User Manual 31 Revision 01 01 February 2019 7 CONTENT OF THE PACKAGE The sensor is delivered complete with Sensor Vega Smart HS0101 1 pc CR123A battery 1 pc Factory certificate 1 pc...

Page 32: ...specified in this user manual Warranty does not apply to power supplies of devices sending more than 15 000 packets the device with mechanical electrical and or other damages and defects caused by vi...

Page 33: ...Smart HS0101 User Manual 33 Revision 01 01 February 2019 vega absolute ru Operation Manual Vega Absolute LLC 2019...

Reviews: