Smart-HS0101 / User Manual
6
Revision
№ 01 - 01 February 2019
When measurements are out of specified temperature/humidity range the
communication period still the same if parameter “Immediately send data when temperature
is out of range” is not active. If that parameter is active then the alarm message will forming
and sending during 2 minutes after the moment of temperature/humidity measurements are
out of specified range. Every following message, which will form according to the data
collection period, will have sent according to the communication period.
With the "Confirmed uplinks" option turned on, the device will send the next packet
only after receiving a confirmation of the delivery of the previous one. If such confirmation
have not received after the fulfilled in the settings uplink number of transmission, device
completes the communication session until the next one according to the schedule. In this
case, the device continues to collect data according to the data collection period and store it
in memory. Non-transmitted packets remain in the device memory until the next
communication session.
With the "Confirmed uplinks" option turned off, the device just sends all accumulated
packets to the network in order from the earliest to the latest. There are no checks of package
delivery in this mode. There are no non-transmitted messages in the device memory.
The internal clock is set automatically when device connected to the "Vega LoRaWAN
Configurator" via USB, also adjustable via LoRaWAN.
FUNCTIONAL
Vega Smart-HS0101 sensor is class A device (LoRaWAN classification) and has the
following features:
o
Frequency plans RU868, EU868, IN865, AS923, AU915, KR920, US915, KZ865
supported
o
ADR support (Adaptive Data Rate)
o
Sending of confirmed packets (configurable)
o
OTAA or ABP activation (configurable)
o
Communication period - every 5, 15, 30 minutes, 1, 6, 12, 24 hours
(configurable)
o
Extra communication in case of Hall sensor triggering
o
Extra communication in case of accelerometer triggering
o
Extra communication in case of humidity value come out of specified range
o
Extra communication in case of temperature value come out of specified range
o
Temperature and humidity measurements
o
Battery charge measurment (%)
o
Sensitivity: up to -138dBm
o
Saving collected data in “black box” for the next transmitting