1570
16 ETHERNET INSTRUCTIONS
16.5 Executing the Protocols Registered for the Predefined Protocol Support Function
Precautions
• If an error occurs in the mth protocol while multiple protocols are being executed, the instruction does not execute the
"m+1"th protocol and after and is completed with an error.
• The connections for which the GP.ECPRTCL instruction can be executed are only those for which "Communication
protocol" is specified for the communication means.
• If a cancel request is received during execution of the mth protocol while multiple protocols are executed continuously, the
Ethernet module stores the protocol number m being executed in the device specified by (s3)+0, the receive packet
number successful in collation match for the already executed protocol in the device specified by 1 to (m-1), and the
protocol cancel request error (error code: C404H) in the device specified by (s3)+1.
• When a protocol including no-conversion variables is executed, the total data length of the variables used in one packet
may exceed 1920 bytes. In this case, the instruction may obtain CPU device values over several scans. Therefore, do not
change the CPU device values specified in non-conversion variables from the start of the dedicated instruction to the end of
execution.
• The intelligent function module device (buffer memory) is not affected by the sequence scan of the CPU module and
therefore can process protocols faster than assigning programmable controller devices to variables.
• If protocol setting data is written during execution of the GP.ECPRTCL instruction, the protocol in execution is canceled
upon completion of writing and the instruction is completed with a protocol setting data write error (error code: C430H).
• If the fixed buffer send/receive mode (such as send) of the specified connection has an invalid combination with the
communication type of the protocol to be executed (such as receive only) while the connection number of the Ethernet
module is one from 1 to 16, the GP.ECPRTCL instruction is completed with a connection number setting error (error code:
C407H).
• If the receive waiting time is set to "0: Infinite wait", the GP.ECPRTCL instruction is not completed until the data specified in
the protocol setting is received.
Operation error
Error code
((s3)+1)
Description
C000H to CFFFH
MELSEC iQ-R Ethernet User's Manual (Application)
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......