1626
18 CC-LINK IE FIELD NETWORK INSTRUCTIONS
18.6 Reading the Module Status Information of an Intelligent Device Station
*1 A channel used only for the SINFTYRD and SINFSTRD instructions. The same channel used for the remote instructions (such as
REMFR and REMTO instructions) and the link dedicated instructions (such as the READ and SEND instructions) can be set.
Processing details
• These instructions read the status information of modules and units used in an intelligent device station, and store the data
to the device specified by (d1) and later.
• The following table lists the values to be stored in the corresponding words.
+12
Clock data
(Set only in an
abnormal state)
Upper 8 bits: Month (01H to 12H)
Lower 8 bits: Year (00H to 99H: Lower two digits of the year)
System
+13
Upper 8 bits: Hour (00H to 23H)
Lower 8 bits: Day (01H to 31H)
System
+14
Upper 8 bits: Second (00H to 59H)
Lower 8 bits: Minute (00H to 59H)
System
+15
Upper 8 bits: Year (00H to 99H: Upper two digits of the year)
Lower 8 bits: Day of the week (00H (Sun.) to 06H (Sat.))
System
+16
Error detection network
number
The network number of the station in which an error was detected is stored. (No
information is stored if an error is detected in the own station.)
• 1 to 239 (Network number)
System
+17
Error-detected station
number
The station number of the station where an error was detected is stored. (No
information is stored if an error is detected in the own station.)
• 125: Master station
• 1 to 120: Local station, intelligent device station, submaster station
System
Operand
Item
(d1)+0 to (d1)+3
Main base unit: power supply information 1
(d1)+4 to (d1)+7
Main base unit: power supply information 2
(d1)+8 to (d1)+11
1st extension base unit: power supply information 1
(d1)+12 to (d1)+15
1st extension base unit: power supply information 2
(d1)+56 to (d1)+59
7th extension base unit: power supply information 1
(d1)+60 to (d1)+63
7th extension base unit: power supply information 2
(d1)+64 to (d1)+67
Main base unit information
(d1)+68 to (d1)+71
1st extension base unit information
(d1)+92 to (d1)+95
7th extension base unit information
(d1)+96 to (d1)+99
CPU slot: product information
(d1)+100 to (d1)+103
I/O slot 0: product information
(d1)+104 to (d1)+107
I/O slot 1: product information
(d1)+352 to (d1)+355
I/O slot 63: product information
Operand: (s)
Device
Item
Description
Setting range
Set by
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......