15 NETWORK COMMON INSTRUCTIONS
15.1 Link Dedicated Instructions
1477
15
Writing data to the programmable controller on another station
(with notification)
JP.SWRITE, GP.SWRITE
These instructions write data to a device in the programmable controller of another station (in units of words).
After the data writing is completed by the SWRITE instruction, the device of another station is turned on. The other station can
recognize that data has been written by the SWRITE instruction.
■
Execution condition
Setting data
■
Description, range, data type
*1 When specifying setting data by using a label, define an array to secure enough operation area and specify an element of the array
label.
Ladder
ST
ENO:=JP_SWRITE(EN,J,s1,s2,d1,d2,d3);
ENO:=GP_SWRITE(EN,U,s1,s2,d1,d2,d3);
FBD/LD
Instruction
Execution condition
JP.SWRITE
GP.SWRITE
Operand
Description
Range
Data type
Data type (label)
(J/U)
JP.SWRITE
(J): Own station network number
1 to 239
16-bit unsigned binary
ANY16
GP.SWRITE
(U): Start I/O number (first three digits in four-
digit hexadecimal representation) of own station
or own node
00H to FEH
16-bit unsigned binary
ANY16
(s1)
Own station start device where control data is
stored
Refer to the control data.
Device name
ANY16
(s2)
Own station start device containing write data
Device name
ANY16
(d1)
Target station start device to which data is to be
written
String
ANYSTRING_SINGLE
(d2)
Device of the own station, which turns on for one
scan upon completion of the instruction.
When the instruction completes with an error,
(d2)+1 also turns on.
Bit
ANYBIT_ARRAY
(Number of elements: 2)
(d3)
Target station device that is turned on one scan
upon completion of instruction (enabling the
target station to recognize that data has been
written from another station)
String
ANYSTRING_SINGLE
EN
Execution condition
Bit
BOOL
ENO
Execution result
Bit
BOOL
RnCPU RnENCPU
RnSFCPU RnSFCPU
RnPCPU
RnPCPU
(Standard)
(Safety)
(Redundant)
(Process)
(s1)
(s2)
(d1)
(d2)
(d3)
(J/U)
EN
ENO
J/U
s1
d2
s2
d1
d3
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......