Appendix 1 Instruction Processing Time
2025
A
UNIINFRD
(n)=1
13.400
20.000
(When the Process
CPU is used:
22.900)
(n)=16
26.100
33.100
(When the Process
CPU is used:
36.800)
S.RTREAD
2.400
5.900
S.RTWRITE
13.500
43.800
LOGTRG
55.700
74.500
LOGTRGR
11.000
18.600
SP.SOCOPEN
TCP: Active
15.600
33.800
TCP: Unpassive
15.600
33.800
TCP: Fullpassive
15.600
33.800
UDP
15.600
33.800
SP.SOCCLOSE
TCP: Executed from own device
15.300
34.000
TCP: Executed from external device
15.300
34.000
UDP
15.300
34.000
SP.SOCRCV
TCP: Minimum amount of data (1 byte)
15.000
36.700
TCP: Maximum amount of data (10238 bytes)
15.000
36.700
UDP: Minimum amount of data (1 byte)
15.200
36.800
UDP: Maximum amount of data (10238 bytes)
15.200
36.800
S.SOCRCVS
TCP: Minimum amount of data (1 byte)
15.800
32.000
TCP: Maximum amount of data (10238 bytes)
141.000
180.000
UDP: Minimum amount of data (1 byte)
15.800
32.000
UDP: Maximum amount of data (10238 bytes)
145.000
182.000
SP.SOCSND
TCP: Minimum amount of data (1 byte)
18.000
35.400
TCP: Maximum amount of data (10238 bytes)
155.000
180.000
UDP: Minimum amount of data (1 byte)
18.000
35.400
UDP: Maximum amount of data (10238 bytes)
155.000
180.000
SP.SOCCINF
3.100
9.200
SP.SOCCSET
3.300
14.500
SP.SOCRMODE
Switching from normal mode to fixed-length mode
4.800
14.200
Switching from fixed-length mode to normal mode
4.800
13.900
S.SOCRDATA
Minimum amount of data (1 word)
4.200
10.100
Maximum amount of data (5120 words)
114.400
162.800
SP.ECPRTCL
33.200
39.800
SP.SLMPSND
"Read (command: 0401H)" (reading in units of words): Number of read points = 1
point
16.4
41.4
SP.FTPPUT
File name + server path string = 32 characters
76.000
80.000
File name + server path string = 64 characters
93.000
97.000
SP.FTPGET
File name + server path string = 32 characters
76.000
80.000
File name + server path string = 64 characters
93.000
97.000
PSTOP
File name: "P1"
43.000
78.000
POFF
File name: "P1"
42.300
77.000
PSCAN
File name: "P1"
43.700
78.200
PID
3.900
10.200
S.PIDINIT
1 loop
3.500
7.000
32 loop
53.300
56.900
S.PIDCONT
1 loops (first time)
16.600
18.100
1 loops (second and later)
13.900
19.500
32 loops (first time)
205.000
208.700
32 loops (second and later)
193.300
214.100
Instruction name
Condition
Processing time (
s)
Minimum
Maximum
Summary of Contents for MELSEC iQ-R Series
Page 1: ...MELSEC iQ R Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 24: ...22 INDEX 2092 INSTRUCTION INDEX 2093 REVISIONS 2104 WARRANTY 2105 TRADEMARKS 2106 ...
Page 34: ...32 MEMO ...
Page 35: ...33 PART 1 PART 1 OVERVIEW This part consists of the following chapter 1 OVERVIEW ...
Page 68: ...66 1 OVERVIEW 1 5 Precautions on Programming MEMO ...
Page 1448: ...1446 14 REDUNDANT SYSTEM INSTRUCTIONS 14 2 Disabling Enabling System Switching MEMO ...
Page 1972: ...1970 33 TIME DATA TYPE FUNCTIONS 33 4 Division MEMO ...
Page 2067: ...APPX Appendix 5 PID Control Program Examples 2065 A 252 Set PID control data for loop 2 ...
Page 2109: ......