D-99
E2EL
E2
E
L
High Frequency Inductive Proximity Sensor
E2EL
Increased response
frequency for high speed
applications
• Max 5 kHz, switching frequency
• M8 or dia
• 6.5 mm housing
• Brass or stainless steel housing
Ordering Information
Cable types
Brass housing
Stainless steel housing
Plug types
Brass housing
Diameter
Length
Mounting
Sensing
Distance
Output
NPN / NO
NPN / NC
PNP / NO
PNP / NC
Ø
6,5
30 mm
Shielded
1,5 mm
E2EL-C1R5E1 2M
E2EL-C1R5E2 2M
E2EL-C1R5F1 2M
E2EL-C1R5F2 2M
32 mm
Non-shielded
2,0 mm
E2EL-C2ME1 2M
E2EL-C2ME2 2M
E2EL-C2MF1 2M
E2EL-C2MF2 2M
45 mm
Shielded
1,5 mm
E2EL-C1R5E1-L 2M
E2EL-C1R5E2-L 2M
E2EL-C1R5F1-L 2M
E2EL-C1R5F2-L 2M
47 mm
Non-shielded
2,0 mm
E2EL-C2ME1-L 2M
E2EL-C2ME2-L 2M
E2EL-C2MF1-L 2M
E2EL-C2MF2-L 2M
M8
30 mm
Shielded
1,5 mm
E2EL-X1R5E1 2M
E2EL-X1R5E2 2M
E2EL-X1R5F1 2M
E2EL-X1R5F2 2M
32 mm
Non-shielded
2,0 mm
E2EL-X2ME1 2M
E2EL-X2ME2 2M
E2EL-X2MF1 2M
E2EL-X2MF2 2M
45 mm
Shielded
1,5 mm
E2EL-X1R5E1-L 2M
E2EL-X1R5E2-L 2M
E2EL-X1R5F1-L 2M
E2EL-X1R5F2-L 2M
47 mm
Non-shielded
2,0 mm
E2EL-X2ME1-L 2M
E2EL-X2ME2-L 2M
E2EL-X2MF1-L 2M
E2EL-X2MF2-L 2M
Diameter
Length
Mounting
Sensing
Distance
Output
NPN / NO
NPN / NC
PNP / NO
PNP / NC
Ø
6,5
30 mm
Shielded
2,0 mm
E2EL-C2E1-DS 2M
E2EL-C2E2-DS 2M
E2EL-C2F1-DS 2M
E2EL-C2F2-DS 2M
45 mm
Shielded
2,0 mm
E2EL-C2E1-DSL 2M E2EL-C2E2-DSL 2M
E2EL-C2F1-DSL 2M
E2EL-C2F2-DSL 2M
M8
30 mm
Shielded
2,0 mm
E2EL-X2E1-DS 2M
E2EL-X2E2-DS 2M
E2EL-X2F1-DS 2M
E2EL-X2F2-DS 2M
45 mm
Shielded
2,0 mm
E2EL-X2E1-DSL 2M
E2EL-X2E2-DSL 2M
E2EL-X2F1-DSL 2M
E2EL-X2F2-DSL 2M
Diameter
Length
Mounting
Sensing
Distance
Output
NPN / NO
NPN / NC
PNP / NO
PNP / NC
Ø
6,5 /
Plug M8
45 mm
Shielded
1,5 mm
E2EL-C1R5E1-M3
E2EL-C1R5E2-M3
E2EL-C1R5F1-M3
E2EL-C1R5F2-M3
47 mm
Non-shielded
2,0 mm
E2EL-C2ME1-M3
E2EL-C2ME2-M3
E2EL-C2MF1-M3
E2EL-C2MF2-M3
54 mm
Shielded
1,5 mm
E2EL-C1R5E1-M3L
E2EL-C1R5E2-M3L
E2EL-C1R5F1-M3L
E2EL-C1R5F2-M3L
56 mm
Non-shielded
2,0 mm
E2EL-C2ME1-M3L
E2EL-C2ME2-M3L
E2EL-C2MF1-M3L
E2EL-C2MF2-M3L
M8 /
Plug M8
45 mm
Shielded
1,5 mm
E2EL-X1R5E1-M3
E2EL-X1R5E2-M3
E2EL-X1R5F1-M3
E2EL-X1R5F2-M3
47 mm
Non-shielded
2,0 mm
E2EL-X2ME1-M3
E2EL-X2ME2-M3
E2EL-X2MF1-M3
E2EL-X2MF2-M3
54 mm
Shielded
1,5 mm
E2EL-X1R5E1-M3L
E2EL-X1R5E2-M3L
E2EL-X1R5F1-M3L
E2EL-X1R5F2-M3L
56 mm
Non-shielded
2,0 mm
E2EL-X2ME1-M3L
E2EL-X2ME2-M3L
E2EL-X2MF1-M3L
E2EL-X2MF2-M3L
M8 /
Plug M12
44 mm
Shielded
1,5 mm
E2EL-X1R5E1-M1
E2EL-X1R5E2-M1
E2EL-X1R5F1-M1
E2EL-X1R5F2-M1
46 mm
Non-shielded
2,0 mm
E2EL-X2ME1-M1
E2EL-X2ME2-M1
E2EL-X2MF1-M1
E2EL-X2MF2-M1
60 mm
Shielded
1,5 mm
E2EL-X1R5E1-M1L
E2EL-X1R5E2-M1L
E2EL-X1R5F1-M1L
E2EL-X1R5F2-M1L
62 mm
Non-shielded
2,0 mm
E2EL-X2ME1-M1L
E2EL-X2ME2-M1L
E2EL-X2MF1-M1L
E2EL-X2MF2-M1L
F502-EN2-04.book Seite 99 Dienstag, 26. Juli 2005 5:48 17