D-100

Inductive Sensors

Specifications

Brass type

Type

Ø

 6,5

M8

Operating voltage

10 to 35 VDC

Rated supply voltage

24 VDC

Current consumption

max. 15 mA at 24 VDC

Sensing object

Ferrous metals

Mounting ((s)hielded, (n)on-shielded) *1

*1.

For detailed mounting instruction please refer to page D-105

s

n

s

n

Operating distance in mm

1,5

2,0

1,5

2,0

Tolerance of operating distance

±10%

Standard target size in mm (L x W x H in mm, FE 37)

6,5x6,5x1

8x8x1

Differential travel

1 % ... 15 % of operating distance

Max. response frequency in kHz

5,0

Control output

Type

E2EL-... E1 type: NPN-NO

E2 type: NPN-NC

F1 type: PNP-NO

F2 type: PNP-NC

Max-Load

200 mA

Max-on-state
Voltage drop

2,5 VDC (at 200mA load current and with 2 m cable)

Circuit protection

Reverse polarity, output short-circuit

Indicator

Operating indicator (yellow LED)

Ambient temperature

Operating: -25° to 70°C

Humidity

35 to 95 % RH

Influence of temperature

± 10 % max. of Sn at 23°C in temperature range of -25° to 70°C

Dielectric strength

1.500 VAC, 50/60 Hz for 1 min. between current carry parts and 
case

Electromagnetic compatibility EMC

EN 60947-5-2

Vibration resistance

Destruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each 
in X, Y and Z directions

Shock resistance

Destruction: 300 m/s² (approx. 30 G) for 6 times each in X, Y and Z 
directions

Enclosure rating

IP 67 (EN 60947-1)

Connection  *2

*2.

PUR cable and different length on request.

Pre-wired

2 m PVC-cable, 3 x 0,14 mm²

Connector

M8 plug 

Weight in g

Pre-wired

long

45

50

short

43

48

Connector

long

10

15

short

8

13

Material

Case

Brass

Sensing face

PBTP

F502-EN2-04.book  Seite 100  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for E2EL

Page 1: ...L C2F1 DS 2M E2EL C2F2 DS 2M 45 mm Shielded 2 0 mm E2EL C2E1 DSL 2M E2EL C2E2 DSL 2M E2EL C2F1 DSL 2M E2EL C2F2 DSL 2M M8 30 mm Shielded 2 0 mm E2EL X2E1 DS 2M E2EL X2E2 DS 2M E2EL X2F1 DS 2M E2EL X2F2 DS 2M 45 mm Shielded 2 0 mm E2EL X2E1 DSL 2M E2EL X2E2 DSL 2M E2EL X2F1 DSL 2M E2EL X2F2 DSL 2M Diameter Length Mounting Sensing Distance Output NPN NO NPN NC PNP NO PNP NC Ø 6 5 Plug M8 45 mm Shiel...

Page 2: ... load current and with 2 m cable Circuit protection Reverse polarity output short circuit Indicator Operating indicator yellow LED Ambient temperature Operating 25 to 70 C Humidity 35 to 95 RH Influence of temperature 10 max of Sn at 23 C in temperature range of 25 to 70 C Dielectric strength 1 500 VAC 50 60 Hz for 1 min between current carry parts and case Electromagnetic compatibility EMC EN 609...

Page 3: ...Circuit protection Reverse polarity output short circuit Indicator Operating indicator yellow LED Ambient temperature Operating 25 to 70 C Humidity 35 to 95 RH Influence of temperature 10 max of Sn at 23 C in temperature range of 25 to 70 C Dielectric strength 1 500 VAC 50 60 Hz for 1 min between current carry parts and case Electromagnetic compatibility EMC EN 60947 5 2 Vibration resistance Destr...

Page 4: ...curve switch off curve axial distance related to effective operating distance s s r on E2EL E NPN Output E2EL F PNP Output Main circuit Brown 1 Blue 3 Load Black 4 or 2 Blue 3 Load Black 4 or 2 Brown 1 0 V Main circuit 4 7 kW 4 7 kW Sensing object Yellow indicator Control output Yes No ON OFF Lit Not lit NO NC E2EL E NPN Output Sensing object Yellow indicator Control output Yes No ON OFF Lit Not l...

Page 5: ...103 E2EL E2EL Dimensions Cable types E2EL C1 R5 2M E2EL C2 DS 2M E2EL C2M 2M E2EL C1R5 L 2M E2EL C2 DSL 2M E2EL C2M L 2M E2EL X1R5 2M E2EL X2 DS 2M E2EL X2M 2M E2EL X1R5 L 2M E2EL X2 DSL 2M E2EL X2M L 2M ...

Page 6: ... 104 Inductive Sensors Plug types E2EL C1R5 M3 E2EL C2M M3 E2EL C1R5 M3L E2EL C2M M3L E2EL X1R5 M3 E2EL X2M M3 E2EL X1R5 M3L E2EL X2 DM3S E2EL X2M M3L E2EL X1R5 M1 E2EL X2M M1 E2EL X1R5 M1L E2EL X2M M1L ...

Page 7: ... Mounting The Proximity Sensor must not be subjected to excessive shock with a ha mmer when it is installed otherwise the Proximity Sen sor may be damaged or lose the water resistivity Environment Water Resistivity Do not use the Proximity Sensor underwater outdoors or in the rain Operating Environment Be sure to use the Proximity Sensor within operating ambient temperature range and do not use th...

Page 8: ... The Sensors connected together must satisfy the following conditions iL N 1 x i Upper limit of control output of each Sensor VS N x VR Load operating voltage N No of Sensors VR Residual voltage of each Sensor VS Supply voltage i Current consumption of the Sensor iL Load current If the MY Relay which operate at 24 VDC is used as a load for example a maximum of two Proximity Sensors can be connecte...