background image

D-105

E2EL

E2

E

L

Installation

Caution

Correct Use

Installation

Power Reset Time

The Proximity Sensor is ready to operate within 100 ms after 
power is supplied. If power supplies are connected to the Proxim-
ity Sensor and load respectively, be sure to supply power to the 
Proximity Sensor before supplying power to the load.

Power OFF

The Proximity Sensor may output a pulse signal when it is turned 
off. Therefore, it is recommended to turn off the load before turn-
ing off the Proximity Sensor.

Power Supply Transformer

When using a DC power supply, make sure that the DC power 
supply has an insulated transformer. Do not use a DC power sup-
ply with an auto-transformer.

Sensing Object

Metal Coating:
The sensing distance of the Proximity Sensor vary with the metal 
coating on sensing objects.

Wiring

High-tension Lines

Wiring through Metal Conduit
If there is a power or high-tension line near the cord of the Prox-
imity Sensor, wire the cord through an independent metal conduit 
to prevent against Proximity Sensor damage or malfunctioning.

Core Tractive Force

Do not pull cords with the tractive force exceeding the following: 
pull force (N) = 20 x cable diameter ( mm)

Mounting

The Proximity Sensor must not be subjected to excessive shock 
with a ha mmer when it is installed, otherwise the Proximity Sen-
sor may be damaged or lose the water-resistivity.

Environment

Water-Resistivity

Do not use the Proximity Sensor underwater, outdoors or in the 
rain.

Operating Environment

Be sure to use the Proximity Sensor within operating ambient 
temperature range and do not use the Proximity Sensor outdoors 
so that its reliability and life expectancy can be maintained. Al-
though the Proximity Sensor is water resistive, a cover to protect 
the Proximity Sensor from water or soluble machining oil is reco 
mmended so that its reliability and life expectancy can be main-
tained. Do not use the Proximity Sensor in an environment with 
chemical gas (e. G., strong alkaline or acid gases including nitric, 
chromic, and concentrated sulfuric acid gases).

Item

Examples

Power Supply

Do not impose an excessive voltage on the E2EL, otherwise it may 
explode or burn. 
Do not impose 24 VAC on any E2EL model, otherwise it may ex-
plode or burn.

Load short-circuit

Do not short-circuit the load, or the E2EL may explode or burn.
The E2EL's short-circuit protection function is valid, if the polarity of 
the supply voltage imposed is incorrect and within the rated voltage 
range.

Wiring

Be sure to wire the E2EL and load correctly, otherwise it may ex-
plode or burn.

F502-EN2-04.book  Seite 105  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for E2EL

Page 1: ...L C2F1 DS 2M E2EL C2F2 DS 2M 45 mm Shielded 2 0 mm E2EL C2E1 DSL 2M E2EL C2E2 DSL 2M E2EL C2F1 DSL 2M E2EL C2F2 DSL 2M M8 30 mm Shielded 2 0 mm E2EL X2E1 DS 2M E2EL X2E2 DS 2M E2EL X2F1 DS 2M E2EL X2F2 DS 2M 45 mm Shielded 2 0 mm E2EL X2E1 DSL 2M E2EL X2E2 DSL 2M E2EL X2F1 DSL 2M E2EL X2F2 DSL 2M Diameter Length Mounting Sensing Distance Output NPN NO NPN NC PNP NO PNP NC Ø 6 5 Plug M8 45 mm Shiel...

Page 2: ... load current and with 2 m cable Circuit protection Reverse polarity output short circuit Indicator Operating indicator yellow LED Ambient temperature Operating 25 to 70 C Humidity 35 to 95 RH Influence of temperature 10 max of Sn at 23 C in temperature range of 25 to 70 C Dielectric strength 1 500 VAC 50 60 Hz for 1 min between current carry parts and case Electromagnetic compatibility EMC EN 609...

Page 3: ...Circuit protection Reverse polarity output short circuit Indicator Operating indicator yellow LED Ambient temperature Operating 25 to 70 C Humidity 35 to 95 RH Influence of temperature 10 max of Sn at 23 C in temperature range of 25 to 70 C Dielectric strength 1 500 VAC 50 60 Hz for 1 min between current carry parts and case Electromagnetic compatibility EMC EN 60947 5 2 Vibration resistance Destr...

Page 4: ...curve switch off curve axial distance related to effective operating distance s s r on E2EL E NPN Output E2EL F PNP Output Main circuit Brown 1 Blue 3 Load Black 4 or 2 Blue 3 Load Black 4 or 2 Brown 1 0 V Main circuit 4 7 kW 4 7 kW Sensing object Yellow indicator Control output Yes No ON OFF Lit Not lit NO NC E2EL E NPN Output Sensing object Yellow indicator Control output Yes No ON OFF Lit Not l...

Page 5: ...103 E2EL E2EL Dimensions Cable types E2EL C1 R5 2M E2EL C2 DS 2M E2EL C2M 2M E2EL C1R5 L 2M E2EL C2 DSL 2M E2EL C2M L 2M E2EL X1R5 2M E2EL X2 DS 2M E2EL X2M 2M E2EL X1R5 L 2M E2EL X2 DSL 2M E2EL X2M L 2M ...

Page 6: ... 104 Inductive Sensors Plug types E2EL C1R5 M3 E2EL C2M M3 E2EL C1R5 M3L E2EL C2M M3L E2EL X1R5 M3 E2EL X2M M3 E2EL X1R5 M3L E2EL X2 DM3S E2EL X2M M3L E2EL X1R5 M1 E2EL X2M M1 E2EL X1R5 M1L E2EL X2M M1L ...

Page 7: ... Mounting The Proximity Sensor must not be subjected to excessive shock with a ha mmer when it is installed otherwise the Proximity Sen sor may be damaged or lose the water resistivity Environment Water Resistivity Do not use the Proximity Sensor underwater outdoors or in the rain Operating Environment Be sure to use the Proximity Sensor within operating ambient temperature range and do not use th...

Page 8: ... The Sensors connected together must satisfy the following conditions iL N 1 x i Upper limit of control output of each Sensor VS N x VR Load operating voltage N No of Sensors VR Residual voltage of each Sensor VS Supply voltage i Current consumption of the Sensor iL Load current If the MY Relay which operate at 24 VDC is used as a load for example a maximum of two Proximity Sensors can be connecte...

Reviews: