background image

REGISTER YOUR SYSTEM

To activate your warranty, products must be registered within 30 days of purchase.  

Scan the QR code to begin the process or enter the link below.

 

 

chilloutsystems.com/pages/

product-registration

Summary of Contents for QUANTUM PRO

Page 1: ...STER YOUR SYSTEM To activate your warranty products must be registered within 30 days of purchase Scan the QR code to begin the process or enter the link below chilloutsystems com pages product registration ...

Page 2: ...ated Voltage 24V Displacement 1 9cc FAN Axial Flow Rated Voltage 24V Air Volume 220cfm PUMP Rated Voltage 24V Max Flow 20L min OPERTATING TEMPERATURE 32 F 130 F 0 C 54 4 C STORAGE TEMPERATURE 14 F 140 F 0 C 60 C SIZE Length 12 32in 313mm Width 6 69in 170mm Height 6 96in 177mm WEIGHT Cooler 9 92lbs 4 5kg Mounting Plate 1 98lbs 0 9kg SPECIFICATIONS INCLUDED 1x Quantum Pro Cooler 1x Wiring loom 1x Ca...

Page 3: ... to switch to the fluid temperature setting Press again to increase the fluid temperature in increments of 5 degrees farenheit Decrease System Temperature Short press the button to switch to the fluid temperature setting Press again to decrease the fluid temperature in increments of 5 degrees farenheit AIR VOLUME OVERHEAT WARNING SET TEMP COMPRESSOR SPEED SELECTED MODE OVERHEAT WARNING CURRENT TEM...

Page 4: ...tall it and use a sharpie to trace an outline to the vehicle Once the outline has been traced onto your window a rotary cutting tool can be used to cut out the outline We recommend using M4 nuts and bolts to secure the naca duct to a lexan window INSTALLING THE WIRING Connect the wiring harness to the system and run it to your electrical source This can be directly to the battery with an inline fu...

Page 5: ...lt it will automatically shut down The fault code will appear in the Current Temp location on the systems display E1 Temperature Sensor Failure The systems temperature sensor has an error or the systems temperature has exceeded its monitoring range 22 392 F 30 200 C E2 Low voltage protection Compressor input voltage is too low Note The system has a low voltage protection function If the vehicles b...

Page 6: ...6 Copyright Chillout Systems LLC 2022 chilloutsystems com pages gettingstarted Quantum Pro Cooler Installation Guide v1 0 ...

Page 7: ...7 Copyright Chillout Systems LLC 2022 chilloutsystems com pages gettingstarted Quantum Pro Cooler Installation Guide v1 0 ...

Page 8: ...ny time during the 36 month warranty period Deep cleaning of all internals includes fans condenser controller boards Servicing of the cooling s Freon pressure check and top up if necessary Performance checks and optimization In the unlikely event of a failure to your system within your extended warranty we will expedite a replacement cooler to you via Express Air Service Your system will be diagno...

Page 9: ......

Reviews: