Page 1: ...Installation and Operation Manual for Perenio UV Lamp Article PELUV01 PEKUV01 February 2021 ...

Page 2: ......

Page 3: ...s Any reproduction copying publication as well as further distribution or public display of material contained in the present document whether in full or in part shall not be allowed until an appropriate permission of the copyright owner is obtained Any unauthorized usage of materials contained herein may lead to civil liability and criminal prosecution in accordance with applicable laws Any event...

Page 4: ... an outdated version of the document as well as for any possible technical and or typographical errors either omitted or accidental or any related damage that may result from the document transfer or the use of the devices Perenio IoT shall make no guarantee with respect to any data contained herein including but not limited to the device merchantability and fitness for a particular purpose For an...

Page 5: ...azardous Substances RoHS in Electronic and Electrical Equipment 2011 65 EU Directive The device and supplied batteries must not be disposed of as a household waste in accordance with the Waste Electrical and Electronic Equipment Directive 2002 96 EC For the purpose of protection of the environment and human health both the device and batteries must be disposed of in accordance with approved instru...

Page 6: ...forbidden to operate the device if any part of the device is damaged or cracked 6 The device shall not be installed outdoors or near water including humidifiers 7 The device shall be kept away from direct sunlight moisture and vibration 8 It is not allowed to drop or throw the device as well as attempt to repair it on one s own 9 It is not allowed to use the device with a damaged power cord or put...

Page 7: ...ll cause burns 9 To prevent exposure to UV rays the User must disconnect the device from the power source immediately after the disinfection process is finished 10 Please read carefully all instructions and precautions in the QSG and this Operation Manual Failure to follow the manufacturer s instructions may result in fire electric shock and other hazardous situations including human injury Warnin...

Page 8: ... and the Mobile Application of the Company including any future software and hardware whether in house or third party developed are not intended for emergency responses and cannot be used as fire extinguishing equipment and or for emergency intervention including but not limited to fires flooding gas leaks or explosions burglary and theft as well as natural disasters and other force majeure circum...

Page 9: ...3 Scope of Delivery 14 1 4 Packaging and Labelling 15 2 Installation and Setup 16 2 1 Assembly and Preliminary Procedures 16 2 2 General UV Treatment Rules 18 2 2 1 Rules for Remote Operation of the UV Lamp 19 2 2 2 Rules for Manual Operation of the UV Lamp 19 2 2 3 Recommended Exposure Time 19 2 3 Remote Control via Perenio Smart Mobile App 20 2 4 Remote Control via Perenio Lite Mobile App 26 2 5...

Page 10: ... Fi 20 Figure 6 Connection to the mains Without Power Link Wi Fi 31 Table 1 Basic Technical Specifications of the UV Lamp 13 Table 2 Recommended Exposure Time 20 Table 3 Typical Errors and Troubleshooting Methods 38 Connection to the Perenio Smart Mobile App A INSTALLATION OF THE PERENIO SMART MOBILE APP 21 B CONNECTION PROCESS POWER LINK WI FI 22 C SETTING THE TIMER 23 Connection to the Perenio L...

Page 11: ...erated which oxidizes the air thereby destroying bacteria and odor even in hard to reach areas Key functional features of the UV Lamp are Disinfection by ultraviolet and ozone Treatment of large premises Stable illumination and absence of noises due to ballast Long service life of the UV tube Remote control via mobile application if connected to a Power Link device Ease of use no configuration req...

Page 12: ...e connectors Contacts used to insert the UV tube into the lamp bracket Lamp bracket Aluminum base of the UV lamp used for installation of the UV tube Hole for base connectors Slot in edges of the lamp bracket used to insert and remove the UV tube from the lamp bracket UV tube UV lamp component consisting of the bulb and the base Power port Port for connecting the UV lamp to the power source UV tub...

Page 13: ...ity 78μw cm2 Mercury Content 5mg kg max Coverage Area 3m max Coverage angle 240º Power Power 20W Voltage 220 240VAC input 40 100V output Current 100 250mA Frequency 50 60Hz Limit switch type Ballast Operating Temperature 0 С to 40 С Operating Humidity 10 to 90 RH non condensing Storage Temperature 30 С to 60 С Storage Humidity 20 to 90 RH non condensing Casing Protection Class IP20 Installation On...

Page 14: ... of Delivery The following items and accessories are supplied within the Perenio PELUV01 UV Lamp package 1 PELUV01 UV Lamp 1 pc 2 Power cord 2m 1 pc 3 Screws and dowels 1 set 4 Mounting brackets 1 set 5 Cover for unused power port 1 pc 6 Quick Start Guide 1 pc 7 Warranty Card 1 pc 1 2 3 4 Figure 3 Scope of Supply Images of accessories are provided for informational purposes only NOTE The scope of ...

Page 15: ...enio UV Lamp is supplied in a carton gift box of 655mm х 86mm х 55mm LхWхH containing the full name and marking of the device the list of accessories provided and basic technical specifications thereof as well as the date of manufacture and information about the manufacturing plant of devices Weights of the package are as follows Net weight 195g Gross weight 260g ...

Page 16: ... Availability of the power source at the installation area of the UV lamp Lack of plants paintings and fabric interior items Ability to shut down air circulation in the room i e tightly close windows and doors turn off the supply and exhaust ventilation and block the air ducts Below see possible installation locations for the UV Lamp Figure 4 Examples of installation Images are provided for inform...

Page 17: ...et as follows Hold the base of the UV tube with the hand and rotate it in the lamp bracket until the connector is visible in the hole for base connectors Pull the UV tube base slightly in order to remove it from the lamp bracket 4 Insert the lamp bracket into the mounting brackets 5 Carefully remove dirt dust and fingerprints from the UV tube with a cotton cloth wet with alcohol ...

Page 18: ...dows tightly turn off the air conditioner and or block air ducts at the treatment site 9 Select the way to control the UV lamp as follows Remote control via the Perenio Smart Perenio Lite mobile app using the Power Link smart plug or through voice assistants Manual control The UV lamp is deemed to be installed and ready for use 2 2 General UV Treatment Rules ATTENTION Please read Warnings and Rest...

Page 19: ...efore being used by people and or animals 5 Assign an appropriate name for the smart plug turning the UV lamp on and off in such a way as to easily distinguish it in the list of other smart plugs activated in the mobile application for example UV lamp in the kitchen Smart plug for UV lamp 2 2 2 Rules for Manual Operation of the UV Lamp 1 Turn the device on and off with dry hands only 2 Before oper...

Page 20: ...w see the way to connect the UV Lamp to the mains if remotely controlled Figure 5 Connection to the mains With Power Link Wi Fi NOTE The Power Link PEHPL01 PEHPL04 device is activated in the mobile app via the Perenio IoT Router or the Control Gateway while the Power Link Wi Fi PEHPL10 device is activated directly to the app 1 Install the Perenio Smart mobile application and activate the Power Lin...

Page 21: ...agement System app from Google Play or App Store b Register a new User Account or sign in to an existing User Account as follows Registration o Fill in your e mail address user name and password 8 or more symbols including at least one capital letter and one number o select the country of residence o Agree to General Terms of Privacy Policy o Click on the SIGN UP button o The User will receive an ...

Page 22: ... Before connecting make sure that the smart plug is powered on and that the smartphone is located at a distance of not more than 2 meters from it e Press and hold the power button until the LED indicator starts blinking f Clink on START SEARCHING button g Wait for the connection process to be completed NOTE If any failures follow instructions specified on corresponding screens of the smartphone Af...

Page 23: ...s presets for the device NOTE that available options to set timers depend on the selected action for the smart plug turning on or off Setting the scheduled timer to turn on the Power Link Wi Fi 1 Click on the Scheduled Timer button in the device control panel Then click on the icon in the right upper corner of the screen 2 In the Add scheduled event screen select the power type Turn on 3 Select th...

Page 24: ... timer by clicking on it in the list of timers NOTE If the User shall try to change settings of an activated timer it will be automatically disabled A maximum of fifteen 15 weekly timers can be activated at a time Setting the scheduled timer to turn off the Power Link Wi Fi 1 Click on the Scheduled Timer button in the device control panel Then click on the icon in the right upper corner of the scr...

Page 25: ...the Save button 7 Activate the timer in the list 8 The User may make changes to the created timer by clicking on it in the list of timers NOTE If the User shall try to change settings of an activated timer it will be automatically disabled A maximum of fifteen 15 weekly timers can be activated at a time Deleting the weekly timer To delete a timer the User shall slide a finger over it from left to ...

Page 26: ...nt and leave it 5 Use the Power Link Wi Fi device functionality to remotely turn on and off the UV lamp via the mobile application using timers and power on off function See par F below D INSTALLATION OF THE PERENIO LITE MOBILE APP The device shall be managed via a free mobile application available for downloading in Google Play or App Store In order to log in to the User Account follow the steps ...

Page 27: ...I a Click on the icon in the Home tab b Select Socket Wi Fi in the Electrician Section c Enter the password from the Wi Fi Network or select another network NOTE The device may be connected to Wi Fi Network of 2 4GHz only d Click on the CONNECT button NOTE Before connecting make sure that the smart plug is powered on and that the smartphone is located at a distance of not more than 2 meters from i...

Page 28: ...reen once again The smart plug will be displayed in the Home tab F SETTING OF TIMERS There are 2 kinds of timers in the control panel namely Weekly timer and Countdown timer The weekly timer is used to automatically turn on and or off the smart plug at a specified time on specified days of the week The countdown timer allows the User to turn on or off the device automatically after the specified t...

Page 29: ...ush notifications for the timer if required NOTE that push notification activation is optional 5 Select the action to be performed by the timer turning the device on or off 6 Click on the Save button 7 Activate the timer in the list 8 The User may make changes to the created timer by clicking on it in the list of timers NOTE To delete a timer the User shall slide a finger over it from right to lef...

Page 30: ...iate state To save the timer settings click on the OK button The device on off time will be displayed in the control panel For details on the functionality of smart plugs see corresponding manuals downloadable from perenio com 2 5 Management via Voice Assistants To control the smart plug via the Google Home Yandex Smart Home Alice Amazon Alexa Apple Siri or Marusia Mail ru applications it must be ...

Page 31: ...ontrolled Figure 6 Connection to the mains Without Power Link Wi Fi ATTENTION In the case of manual control the User must comply with the rules for staying in UV treated room i e wear special eye and skin protection The manual control of the UV lamp shall be as follows 1 To turn on the UV lamp the User shall connect it to the mains with a cable 2 To turn off the UV lamp the User shall disconnect i...

Page 32: ...s Section The Perenio Smart Health UV Lamp repairs shall be carried out in Service Centers The UV Tube cannot be repaired due to mercury content In the case of warranty repairs or replacement the User shall provide the Seller with the sales receipt and the purchased device For details on the replacement and repairs of the Perenio Smart Health UV Lamp please contact your local Company representativ...

Page 33: ...or a duly filled Warranty Card It shall be also allowed to provide the original of the sales cashier s receipt or such other documentary evidence of the fact and the date of sale of the device The date of sale shall be the date indicated on the sales cashier s receipt or other relevant document If the date of sale is not possible to be determined the start of the warranty period shall be the date ...

Page 34: ... including repair works using unauthorized spare parts Any defects or damage caused by improper or unintended use of the device including operation contrary to available manuals Any defects caused by natural wear and tear of Products including bags casings batteries or Installation and Operation Manuals In the event when the Serial Number Name Plates the date of manufacture or the Model name on th...

Page 35: ...ITIES DUE TO THE FACT THAT THE DEVICE WAS RECOGNIZED AS FAULTY DEFECTIVE OR NOT ALLOWED FOR USAGE The present limited warranty shall provide the Customer with certain legal rights The Customer may also have other rights in accordance with the local consumer protection laws that vary from country to country and may not coincide with this limited warranty For full understanding of the Customer s rig...

Page 36: ... due to their potential to cause harm to the environment To dispose of a device that contains mercury the User must take it to their local recycling facility due to the following reasons If the UV tube is damaged mercury vapors will be released into the air water and or soil and contaminate it as well as may bring harm to human health if the vapors are inhaled The UV lamp components may also need ...

Page 37: ...prus Quality Claims Acceptance and Warranty Service Company Name ASBISc Enterprises PLC Address 43 Kolonakiou Street Diamond Court Ayios Athanasios 4103 Limassol Cyprus Czech Republic Name ASBIS CZ s r o Address Obchodní 103 Čestlice 25101 Info on Certificates and Declarations Certificates Certificate of Compliance CE BSTXD200414778601SC as of April 7 2020 Certificate of Compliance RoHS BST2004147...

Page 38: ...and problems that may occur in the process of using the UV Lamp Table 3 Typical Errors and Troubleshooting Methods Item No Problem Possible Reasons Solution 1 UV Lamp does not turn on The UV tube does not fit tightly to the lamp bracket Reassemble the UV lamp 2 UV tube is not working UV tube is damaged Replace the UV tube Service life of the UV tube has ended Replace the UV tube ...

Page 39: ...sary UV C Electromagnetic spectrum of ultraviolet light determined by the short wave range with a wavelength of 280 100 nm IP20 The degree of protection of the device indicating that parts inside the case are protected from the penetration of fingers or objects longer than 80 mm and solid bodies larger than 12 mm No moisture protection ...