Chapter 7: Using the Web Interface
393
Event/context
Default message when the event = TRUE Default message when the event =
FALSE
LHX/SHX > Sensor Failure
A sensor failure (broken or short circuit)
occurred on LHX at [PORTTYPE] port
'[PORTID]' at sensor '[LHXSENSORID]'.
LHX/SHX > Fan Failure
A fan motor failure occurred on LHX at
[PORTTYPE] port '[PORTID]' at fan
'[LHXFANID]'.
LHX/SHX > Power Supply Failure
A power supply failure occurred on LHX at
[PORTTYPE] port '[PORTID]' at power
supply '[LHXPOWERSUPPLYID]'.
LHX/SHX > Threshold Air Inlet
The air inlet temperature threshold on
LHX at [PORTTYPE] port '[PORTID]' was
crossed.
The air inlet temperature on LHX at
[PORTTYPE] port '[PORTID]' is within
thresholds.
LHX/SHX > Threshold Air Outlet
The air outlet temperature threshold on
LHX at [PORTTYPE] port '[PORTID]' was
crossed.
The air outlet temperature on LHX at
[PORTTYPE] port '[PORTID]' is within
thresholds.
LHX/SHX > Threshold Water Inlet
The water inlet temperature threshold on
LHX at [PORTTYPE] port '[PORTID]' was
crossed.
The water inlet temperature on LHX at
[PORTTYPE] port '[PORTID]' is within
thresholds.
LHX/SHX > Threshold Water Outlet The water outlet temperature threshold
on LHX at [PORTTYPE] port '[PORTID]' was
crossed.
The water outlet temperature on LHX
at [PORTTYPE] port '[PORTID]' is within
thresholds.
LHX/SHX > Voltage Low
The supply voltage on LHX at [PORTTYPE]
port '[PORTID]' is low.
The supply voltage on LHX at
[PORTTYPE] port '[PORTID]' is back to
normal.
LHX/SHX > Threshold Humidity
The humidity threshold on LHX at
[PORTTYPE] port '[PORTID]' was crossed.
The humidity on LHX at [PORTTYPE]
port '[PORTID]' is within thresholds.
LHX/SHX > External Water Cooling
Failure
An external water cooling failure occurred
on LHX at [PORTTYPE] port '[PORTID]'.
LHX/SHX > Water Leak
Water leakage was detected on LHX at
[PORTTYPE] port '[PORTID]'.
The asterisk symbol (*) represents anything you select for the 'trigger' events.
Summary of Contents for Raritan PX3TS
Page 4: ......
Page 6: ......
Page 20: ......
Page 80: ...Chapter 4 Connecting External Equipment Optional 60...
Page 109: ...Chapter 5 PDU Linking 89...
Page 117: ...Chapter 5 PDU Linking 97...
Page 441: ...Chapter 7 Using the Web Interface 421...
Page 464: ...Chapter 7 Using the Web Interface 444...
Page 465: ...Chapter 7 Using the Web Interface 445 Continued...
Page 746: ...Appendix A Specifications 726...
Page 823: ...Appendix I RADIUS Configuration Illustration 803 Note If your PX3TS uses PAP then select PAP...
Page 828: ...Appendix I RADIUS Configuration Illustration 808 14 The new attribute is added Click OK...
Page 829: ...Appendix I RADIUS Configuration Illustration 809 15 Click Next to continue...
Page 860: ...Appendix J Additional PX3TS Information 840...
Page 890: ...Appendix K Integration 870 3 Click OK...
Page 900: ......