Administering EPICenter
EPICenter Reference Guide
366
You can set the following properties to affect the scalability of EPICenter:
NOTE
You should not change the values for traps and syslog messages accepted unless the EPICenter Server reports
dropping lots of traps. Run the
Server State Summary Report
in the Reports applet to view the current performance
metrics.
SNMP Properties
When you select SNMP from the drop-down menu field at the top of the properties panel, you can set
the following properties:
Thread Pool Size
This specifies the maximum number of threads available. The default is 40.
Thread Default Alloc Size
This specifies the default number of threads allocated for a process request. The default
is 20.
Traps per Device in 1/2
Minute
This specifies the maximum number of traps that can be received
from an individual
device
in 28 seconds. If more than this number of traps are received from an individual
device within a 28 second interval, the excess traps are dropped.
Total Traps Accepted per
Minute
This specifies the
maximum total number of traps that EPICenter can receive from all
managed devices
in 55 seconds. If more than this number of traps are received within
a 55 second interval, the excess traps are dropped. The default is 275, the maximum
you can set is 500.
Syslog Messages per
Device in 1/2 Minute
This specifies the maximum number of syslog messages that can be received
from an
individual device
in 28 seconds. If more than this number of traps are received within a
28 second interval, the excess messages are ignored.
Total Syslog Messages
Accepted per Minute
This specifies the maximum number of syslog messages that EPICenter can receive in
one minute from all managed devices. If more than this number of messages are
received within a one-minute interval, the excess messages are ignored. The default is
275, the maximum you can set is 500.
Poll Interval
The interval, in minutes, between SNMP polls of a switch to fetch basic device status
information. The default is five minutes. The range is one minute to one hour. You can
disable all SNMP polling by setting this property to zero.
Note:
This Poll Interval is not the same as the Device Polling Interval you can set
through the Inventory Manager. The Device Polling Interval controls the frequency of
polling for detailed device information such as software version, BootROM version, and
so on. The polling interval set here in the Administration applet controls only the basic
SNMP status information necessary to ensure SNMP reachability, and is typically
performed relatively frequently.
Timeout Period
The length of time, in seconds, to wait for an SNMP poll request to complete, in
milliseconds, before timing out. The default is five seconds. The range is one to 60
seconds.
This setting determines the time-out interval only for the first unsuccessful SNMP
request; once a request times out, subsequent requests will time out more slowly, based
on an exponential time-out back-off algorithm, until it reaches the maximum number of
retries.
Number of Retries
The number of SNMP requests that should be attempted before giving up, for a request
that has timed out. The default is one.
EPICenter Trap Receiver
Port
The port on which EPICenter expects to receive traps. Default is port 10550.
Trap Fowarding:
These provide the default settings for the Trap Forwarding alarm action.
Summary of Contents for EPICenter 6.0
Page 14: ...EPICenter Reference Guide 14 ...
Page 18: ...Preface EPICenter Reference Guide 18 ...
Page 19: ...1 EPICenter Basic Features ...
Page 20: ......
Page 24: ...EPICenter Overview EPICenter Reference Guide 24 ...
Page 44: ...Getting Started with EPICenter EPICenter Reference Guide 44 ...
Page 100: ...The Inventory Manager EPICenter Reference Guide 100 ...
Page 140: ...The EPICenter Alarm System EPICenter Reference Guide 140 ...
Page 172: ...Configuration Manager EPICenter Reference Guide 172 ...
Page 196: ...The Firmware Manager EPICenter Reference Guide 196 ...
Page 220: ...The Interactive Telnet Feature EPICenter Reference Guide 220 ...
Page 250: ...The Grouping Manager EPICenter Reference Guide 250 ...
Page 276: ...Real Time Statistics EPICenter Reference Guide 276 ...
Page 342: ...Using the VLAN Manager EPICenter Reference Guide 342 ...
Page 348: ...The ESRP Monitor EPICenter Reference Guide 348 ...
Page 446: ...EPICenter Reports EPICenter Reference Guide 446 ...
Page 447: ...2 Advanced Upgrade Features ...
Page 448: ......
Page 480: ...EAPS Protocol Monitoring and Verification EPICenter Reference Guide 480 ...
Page 508: ...Using the Policy Manager EPICenter Reference Guide 508 ...
Page 525: ...3 Appendices ...
Page 526: ......
Page 542: ...EPICenter Backup EPICenter Reference Guide 542 ...
Page 564: ...Voice over IP Manager EPICenter Reference Guide 564 ...
Page 580: ...EPICenter Reference Guide 580 ...