37.5.2
Power Management
The PWM is not continuously clocked. The programmer must first enable the
PWM
clock in the
Power Management Controller (PMC) before using the
PWM
. However, if the application does
not require PWM operations, the
PWM
clock can be stopped when not needed and be restarted
later. In this case, the
PWM
will resume its operations where it left off.
In the
PWM
description, Master Clock (MCK) is the clock of the peripheral bus to which the
PWM
is connected.
37.5.3
Interrupt Sources
The
PWM
interrupt line is connected on one of the internal sources of the Interrupt Controller.
Using the
PWM
interrupt requires the Interrupt Controller to be programmed first. Note that it is
not recommended to use the
PWM
interrupt line in edge sensitive mode.
37.5.4
Fault Inputs
The
PWM
has the FAULT inputs connected to the different modules. Please refer to the imple-
mentation of these module within the product for detailed information about the fault generation
procedure. The
PWM
receives faults from PIO inputs, PMC, ADC controller, Analog Comparator
Controller and Timer/Counters
PWM
PWMH3
PC21
B
PWM
PWML0
PA19
B
PWM
PWML0
PB5
B
PWM
PWML0
PC0
B
PWM
PWML0
PC13
B
PWM
PWML1
PA20
B
PWM
PWML1
PB12
A
PWM
PWML1
PC1
B
PWM
PWML1
PC15
B
PWM
PWML2
PA16
C
PWM
PWML2
PA30
A
PWM
PWML2
PB13
A
PWM
PWML2
PC2
B
PWM
PWML3
PA15
C
PWM
PWML3
PC3
B
PWM
PWML3
PC22
B
Table 37-2.
I/O Lines
Table 37-3.
Peripheral IDs
Instance
ID
PWM
31
Summary of Contents for SAM4S Series
Page 44: ...44 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 412: ...412 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 1105: ...1105 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 1143: ...1143 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 4 64 lead LQFP Package Drawing ...
Page 1145: ...1145 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 5 64 lead QFN Package Drawing ...