SAM4S Series [Preliminary]
If an external trigger is used, the duration of the pulses must be longer than the master clock
period in order to be detected.
35.6.7
Capture Operating Mode
This mode is entered by clearing the WAVE parameter in TC_CMR (Channel Mode Register).
Capture Mode allows the TC channel to perform measurements such as pulse timing, fre-
quency, period, duty cycle and phase on TIOA and TIOB signals which are considered as
inputs.
shows the configuration of the TC channel when programmed in Capture Mode.
35.6.8
Capture Registers A and B
Registers A and B (RA and RB) are used as capture registers. This means that they can be
loaded with the counter value when a programmable event occurs on the signal TIOA.
The LDRA parameter in TC_CMR defines the TIOA selected edge for the loading of register A,
and the LDRB parameter defines the TIOA selected edge for the loading of Register B.
RA is loaded only if it has not been loaded since the last trigger or if RB has been loaded since
the last loading of RA.
RB is loaded only if RA has been loaded since the last trigger or the last loading of RB.
Loading RA or RB before the read of the last value loaded sets the Overrun Error Flag (LOVRS)
in TC_SR (Status Register). In this case, the old value is overwritten.
Summary of Contents for SAM4S Series
Page 44: ...44 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 412: ...412 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 1105: ...1105 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 1143: ...1143 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 4 64 lead LQFP Package Drawing ...
Page 1145: ...1145 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 5 64 lead QFN Package Drawing ...