291
11100B–ATARM–31-Jul-12
SAM4S Series [Preliminary]
15.6.9
RTC Interrupt Enable Register
Name: RTC_IER
Address:
0x400E1480
Access: Write-only
• ACKEN: Acknowledge Update Interrupt Enable
0 = No effect.
1 = The acknowledge for update interrupt is enabled.
• ALREN: Alarm Interrupt Enable
0 = No effect.
1 = The alarm interrupt is enabled.
• SECEN: Second Event Interrupt Enable
0 = No effect.
1 = The second periodic interrupt is enabled.
• TIMEN: Time Event Interrupt Enable
0 = No effect.
1 = The selected time event interrupt is enabled.
• CALEN: Calendar Event Interrupt Enable
0 = No effect.
• 1 = The selected calendar event interrupt is enabled.
• TDERREN: Time and/or Date Error Interrupt Enable
0 = No effect.
• 1 = The time and date error interrupt is enabled.
31
30
29
28
27
26
25
24
–
–
–
–
–
–
–
–
23
22
21
20
19
18
17
16
–
–
–
–
–
–
–
–
15
14
13
12
11
10
9
8
–
–
–
–
–
–
–
–
7
6
5
4
3
2
1
0
–
–
TDERREN
CALEN
TIMEN
SECEN
ALREN
ACKEN