11100B–ATARM–31-Jul-12
SAM4S Series [Preliminary]
• PADV: Padding Value
0 = 0x00 value is used when padding data in write transfer.
1 = 0xFF value is used when padding data in write transfer.
PADV may be only in manual transfer.
• PDCMODE: PDC-oriented Mode
0 = Disables PDC transfer
1 = Enables PDC transfer. In this case, UNRE and OVRE flags in the MCI Mode Register (MCI_SR) are deactivated after
the PDC transfer has been completed.