![Atmel SAM4S Series Preliminary Data Sheet Download Page 222](http://html1.mh-extra.com/html/atmel/sam4s-series/sam4s-series_preliminary-data-sheet_3003408222.webp)
222
11100B–ATARM–31-Jul-12
SAM4S Series [Preliminary]
11.10.1.2
SysTick Reload Value Registers
Name:
SYST_RVR
Access: Read-write
Reset:
0x000000000
The SYST_RVR register specifies the start value to load into the SYST_CVR register.
• RELOAD
Value to load into the SYST_CVR register when the counter is enabled and when it reaches 0.
The RELOAD value can be any value in the range 0x00000001-0x00FFFFFF. A start value of 0 is possible, but has no
effect because the SysTick exception request and COUNTFLAG are activated when counting from 1 to 0.
The RELOAD value is calculated according to its use: For example, to generate a multi-shot timer with a period of N pro-
cessor clock cycles, use a RELOAD value of N-1. If the SysTick interrupt is required every 100 clock pulses, set RELOAD
to 99.
31
30
29
28
27
26
25
24
–
23
22
21
20
19
18
17
16
RELOAD
15
14
13
12
11
10
9
8
RELOAD
7
6
5
4
3
2
1
0
RELOAD