888
11100B–ATARM–31-Jul-12
SAM4S Series [Preliminary]
36.14.7
HSMCI Block Register
Name: HSMCI_BLKR
Address:
0x40000018
Access: Read-write
• BCNT: MMC/SDIO Block Count - SDIO Byte Count
This field determines the number of data byte(s) or block(s) to transfer.
The transfer data type and the authorized values for BCNT field are determined by the TRTYP field in the HSMCI Com-
mand Register (HSMCI_CMDR):
Warning: In SDIO Byte and Block modes, writing to the 7 last bits of BCNT field is forbidden and may lead to unpredictable
results.
• BLKLEN: Data Block Length
This field determines the size of the data block.
This field is also accessible in the HSMCI Mode Register (HSMCI_MR).
Bits 16 and 17 must be set to 0 if FBYTE is disabled.
Note:
In SDIO Byte mode, BLKLEN field is not used.
31
30
29
28
27
26
25
24
BLKLEN
23
22
21
20
19
18
17
16
BLKLEN
15
14
13
12
11
10
9
8
BCNT
7
6
5
4
3
2
1
0
BCNT
Value
Name
Description
0
MULTIPLE
MMC/SDCARD Multiple Block
From 1 to 65635: Value 0 corresponds to an infinite block transfer.
4
BYTE
SDIO Byte
From 1 to 512 bytes: Value 0 corresponds to a 512-byte transfer.
Values from 0x200 to 0xFFFF are forbidden.
5
BLOCK
SDIO Block
From 1 to 511 blocks: Value 0 corresponds to an infinite block transfer.
Values from 0x200 to 0xFFFF are forbidden.
Summary of Contents for SAM4S Series
Page 44: ...44 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 412: ...412 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 1105: ...1105 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 1143: ...1143 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 4 64 lead LQFP Package Drawing ...
Page 1145: ...1145 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 5 64 lead QFN Package Drawing ...