944
11100B–ATARM–31-Jul-12
SAM4S Series [Preliminary]
37.7.11
PWM Sync Channels Update Period Register
Name:
PWM_SCUP
Address:
0x4002002C
Access:
Read-write
• UPR: Update Period
Defines the time between each update of the synchronous channels if automatic trigger of the update is activated
(UPDM = 1 or UPDM = 2 in
“PWM Sync Channels Mode Register” on page 942
). This time is equal to UPR+1 periods of
the synchronous channels.
• UPRCNT: Update Period Counter
Reports the value of the Update Period Counter.
31
30
29
28
27
26
25
24
–
–
–
–
–
–
–
–
23
22
21
20
19
18
17
16
–
–
–
–
–
–
–
–
15
14
13
12
11
10
9
8
–
–
–
–
–
–
–
–
7
6
5
4
3
2
1
0
UPRCNT
UPR