1111
11100B–ATARM–31-Jul-12
SAM4S Series [Preliminary]
42.5
PLLA, PLLB Characteristics
Table 42-21. Supply Voltage Phase Lock Loop Characteristics
Symbol
Parameter
Conditions
Min
Typ
Max
Unit
VDDPLL
Supply Voltage Range
1.08
1.2
1.32
V
Allowable Voltage Ripple
RMS Value 10 kHz to 10 MHz
RMS Value > 10 MHz
20
10
mV
Table 42-22. PLLA and PLLB Characteristics
Symbol
Parameter
Conditions
Min
Typ
Max
Unit
F
IN
Input Frequency
3
32
MHz
F
OUT
Output Frequency
80
240
MHz
I
PLL
Current Consumption
Active mode @ 80 MHz @1.2V
Active mode @ 96 MHz @1.2V
Active mode @ 160 MHz @1.2V
Active Mode @240 MHz @1.2V
0.94
1.2
2.1
3.34
1.2
1.5
2.5
4
mA
T
START
Settling Time
60
150
µS