219
11100B–ATARM–31-Jul-12
SAM4S Series [Preliminary]
11.9.1.17
Bus Fault Address Register
Name:
SCB_BFAR
Access: Read-write
Reset:
0x000000000
The BFAR register contains the address of the location that generated a bus fault.
• ADDRESS
When the BFARVALID bit of the BFSR subregister is set to 1, this field holds the address of the location that generated the
bus fault.
Notes:
1. When an unaligned access faults, the address in the SCB_BFAR register is the one requested by the instruction, even if it is
not the address of the fault.
2. Flags in the BFSR indicate the cause of the fault, and whether the value in the SCB_BFAR register is valid. See
.
31
30
29
28
27
26
25
24
ADDRESS
23
22
21
20
19
18
17
16
ADDRESS
15
14
13
12
11
10
9
8
ADDRESS
7
6
5
4
3
2
1
0
ADDRESS
Summary of Contents for SAM4S Series
Page 44: ...44 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 412: ...412 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 1105: ...1105 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 1143: ...1143 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 4 64 lead LQFP Package Drawing ...