316
11100B–ATARM–31-Jul-12
SAM4S Series [Preliminary]
17.5.4
Supply Controller Supply Monitor Mode Register
Name:
SUPC_SMMR
Address:
0x400E1414
Access:
Read-write
• SMTH: Supply Monitor Threshold
Please refer to Electrical chapter on
Table 42-6 ”Threshold Selection”
(DC Characteristics).
• SMSMPL: Supply Monitor Sampling Period
• SMRSTEN: Supply Monitor Reset Enable
0 (NOT_ENABLE) = the core reset signal “vddcore_nreset” is not affected when a supply monitor detection occurs.
1 (ENABLE) = the core reset signal, vddcore_nreset is asserted when a supply monitor detection occurs.
• SMIEN: Supply Monitor Interrupt Enable
0 (NOT_ENABLE) = the SUPC interrupt signal is not affected when a supply monitor detection occurs.
1 (ENABLE) = the SUPC interrupt signal is asserted when a supply monitor detection occurs.
31
30
29
28
27
26
25
24
–
–
–
–
–
–
–
–
23
22
21
20
19
18
17
16
–
–
–
–
–
–
–
–
15
14
13
12
11
10
9
8
–
–
SMIEN
SMRSTEN
–
SMSMPL
7
6
5
4
3
2
1
0
–
–
–
–
SMTH
Value
Name
Description
0x0
SMD
Supply Monitor disabled
0x1
CSM
Continuous Supply Monitor
0x2
32SLCK
Supply Monitor enabled one SLCK period every 32 SLCK periods
0x3
256SLCK
Supply Monitor enabled one SLCK period every 256 SLCK periods
0x4
2048SLCK
Supply Monitor enabled one SLCK period every 2,048 SLCK periods
0x5-0x7
Reserved
Reserved
Summary of Contents for SAM4S Series
Page 44: ...44 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 412: ...412 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 1105: ...1105 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 1143: ...1143 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 4 64 lead LQFP Package Drawing ...
Page 1145: ...1145 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 5 64 lead QFN Package Drawing ...