791
11100B–ATARM–31-Jul-12
SAM4S Series [Preliminary]
• CTSIC: Clear to Send Input Change Flag
0: No input change has been detected on the CTS pin since the last read of US_CSR.
1: At least one input change has been detected on the CTS pin since the last read of US_CSR.
• RI: Image of RI Input
0: RI is set to 0.
1: RI is set to 1.
• DSR: Image of DSR Input
0: DSR is set to 0
1: DSR is set to 1.
• DCD: Image of DCD Input
0: DCD is set to 0.
1: DCD is set to 1.
• CTS: Image of CTS Input
0: CTS is set to 0.
1: CTS is set to 1.
• MANERR: Manchester Error
0: No Manchester error has been detected since the last RSTSTA.
1: At least one Manchester error has been detected since the last RSTSTA.