283
11100B–ATARM–31-Jul-12
SAM4S Series [Preliminary]
The value obtained must be rounded to the nearest integer prior to being programmed into CORRECTION field.
If HIGHPPM = 1, then the clock frequency correction range is from 30.5 ppm up to 1950 ppm. The RTC accuracy is
less than 1 ppm for a range correction from 30.5 ppm up to 90 ppm.
The correction field must be programmed according to the required correction in ppm, the formula is as follows:
The value obtained must be rounded to the nearest integer prior to be programmed into CORRECTION field.
If NEGPPM is set to 1, the ppm correction is negative.
• OUT0: RTCOUT0 Output Source Selection
• OUT1: RTCOUT1 Output Source Selection
Value
Name
Description
0
NO_WAVE
no waveform, stuck at ‘0’
1
FREQ1HZ
1 Hz square wave
2
FREQ32HZ
32 Hz square wave
3
FREQ64HZ
64 Hz square wave
4
FREQ512HZ
512 Hz square wave
5
ALARM_TOGGLE
output toggles when alarm flag rises
6
ALARM_FLAG
output is a copy of the alarm flag
7
PROG_PULSE
duty cycle programmable pulse
Value
Name
Description
0
NO_WAVE
no waveform, stuck at ‘0’
1
FREQ1HZ
1 Hz square wave
2
FREQ32HZ
32 Hz square wave
3
FREQ64HZ
64 Hz square wave
4
FREQ512HZ
512 Hz square wave
5
ALARM_TOGGLE
output toggles when alarm flag rises
6
ALARM_FLAG
output is a copy of the alarm flag
7
PROG_PULSE
duty cycle programmable pulse
CORRECTION
3906
ppm
-------------
1
–
=
Summary of Contents for SAM4S Series
Page 44: ...44 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 412: ...412 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 1105: ...1105 11100B ATARM 31 Jul 12 SAM4S Series Preliminary ...
Page 1143: ...1143 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 4 64 lead LQFP Package Drawing ...
Page 1145: ...1145 11100B ATARM 31 Jul 12 SAM4S Series Preliminary Figure 43 5 64 lead QFN Package Drawing ...