IDA8 Global-Net User Manual
94
© 2017, ATEÏS, member of PAX ProAV Group
Name
Description
Detail
Solution Way
fail
Can't find DSP
parameter
Re-store again
There is a data error in
the table which stores
important information of
the configuration.
DSP parameter (ats file)
version not matching
Re-store again
There is an internal
hardware error of the
device.
DSP chip
communication fail
If it often shows on front
panel, replace the machine
5v Error
VS_D12V_RL Error
-12v Error
12v Error
48v Error
System 24v Error
Normal 24v Error
BackUp 24v Error
The power circuit inside
the device has an error.
5v, ?2v, 48v, 24v fail
detected
Replace the Machine
Last time the machine is
unpredictably shut
down, please see the
machine log.
Machine is
unpredictable
shutdown at last time,
please see machine log
Contact manufacturer
AESEBU card can't boot.
Update firmware again
The communication
between the main
controller unit and
telephones fails.
Telephone card can't
boot
Update firmware again
There is an Internal
hardware error.
Main board FPGA chip
can't boot
Update firmware again
The global ATEIS net
card fails. Note: Only for
IDA8 global net.
Gocal ATEIS net card
can't boot
Replace the Machine
There has SDRAM fault
in DSP chip.
The SDRAM of DSP chip
error
Replace the Machine
No response on DSP
chip communication.
DSP chip
communication fail
Replace the Machine
An error of DSP default
file and hence no audio
output.
DSP fail
Replace the Machine
3.1.9.2.1 SSI Error
The Audio board control has failed.
Indication: