Data S ec tion
STX
S v v v v
EXT
CR
vvvv = Sub-Preset number
3. Rep ly Read Parameter Command
Command string =Rnnnnvvvv
S TX
Data S ec tion
STX
Rnnnnv v v
S TX
Data S ec tion
STX
Rnnnnv v v
DB element
nnnn = func tion name (fixed 4 leng th)
v v v v = sign + integer(fixed 2 length) + dot + decimal(fixed 1 length)
Other element
Answer is always Rnnnnv v v v (Rep ly Read Para. Com.)
nnnn = func tion name (fixed 4 leng th)
v v v v = value (unfixed)
4. Rep ly Mac hine S y stem V alue
Command string =Pnnnnvvvv
S TX
Data S ec tion
STX
Pnnnnv v v
S TX
Data S ec tion
STX
Pnnnnv v v
nnnn = function name (fixed 4 length)
v v v v = value (unfixed)
5. E thernet Reset Command
Command string = N
S TX
Data S ec tion
STX
N
EXT
CS
CR
S TX
Data S ec tion
STX
N
EXT
CR
Reset Value
IP Address
192,168,100,230
Sub Mask
255,255,255,0
Gateway
192,168,100,254
Receive Port
19760
6. AutoRep ly Control Command
Command string =Bnnnnf
S TX
Data S ec tion
STX
Bnnnnf
EXT
CS
CR
S TX
Data S ec tion
STX
Pnnnnv v v
EXT
CR