Product Features
199
© 2017, ATEÏS, member of PAX ProAV Group
Talk Mode: The behavior of key pressing (Push/Lock) when paging.
Key Count: How many number of keys in PPM-AS.
Key Event: Bind a paging event with PPM-AS for zone selection. See
Paging Key Release Time (sec): Set the release time for paging key. For example, when the release
time is set for two seconds, the paging key will be automatic disable afterwards.
Set the release time as 0, this indicates not to activate this function.
Record (sec.): The time for recording the audio message. Please note users need to enable the Record
function on [PPM-AS Default Settings > Event] window first.
AGC Setting: With this Automatic Gain Control(AGC), the input signal can be increased or decreased to
a target level. You can adjust the gain of the source automatically by setting a target level. For
example, without AGC the sound emitted from an AM radio receiver would vary to the extreme extent
from a weak signal to a strong one. The AGC effectively reduces the volume if the signal is strong or
raises the volume when it's weak.
AGC Enable: Enable or disable the AGC function.
Response Time: Set the attack time at 5(ms) indicating the time when the input level is once under
the threshold value and the gain won't be applied.
Noise Threshold: To detect the audio input volume of AGC and meet the balance of each audio
input level.
Don't set the level too low otherwise it will hear unexpected sounds such as breathing sounds or
ambient noise.
Target Gain: The level will be increased up to target level when audio level is above the threshold
value.
Max Gain: Set the Max Gain which indicates the gain can only be generated up to maximum dB.
Limit the max gain to keep a natural audio dynamic.
3.2.5.3.2 Key Settings
Click the PPM Event button to open the pop-up window.
Left Window:
Paging: Set the key which is corresponded to the zones on PPM-AS. Please create the Integration
Event on Network Paging component first, then the event you created will be listed here.
Double Click: Optional two modes(Single or Double Click) to activate buttons in PPM-AS.
Double Click Interval (sec.): Time interval when activating key buttons in PPM-AS.
Right Window: