IDA8 Global-Net User Manual
76
© 2017, ATEÏS, member of PAX ProAV Group
"Z1 Line Leakage Error", where Z1 can be any zone.
A text message displays at the [Machine Fault Record] window in Ateis Studio:
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Fault Handling : Amplifier Line Leakage Error
Troubleshooting:
1. Plug out the LINE A speaker line, and wait for 90 seconds to check if the Leakage fault has cleared
out or still exists.
2. If there's no Leakage fault, check if the + speaker line is connected to ground wire, and - is
connected ground wire.
3. Send back for repair.
3.1.9.1.7 EVAC Intput Error
The voltage of EVAC input is not in the range (when the evacuation input is set to "contact mode").
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o
G. Fault LED on the front panel of the IDA8C/S.
Log:
o
EVAC Input Error(OPEN)
Text messages display on the touch screen of the IDA8C:
"EVAC Input Error".