IDA8 Global-Net User Manual
434
© 2017, ATEÏS, member of PAX ProAV Group
Control Window
Element Description
(All) Bypass: Disable (all) the Feedback operation.
If the All Bypass button is enabled, all the
captured values will be erased.
(All) Hold: When feedback is detected, a frequency will lock the component to hold this setting.
Enable this button if you don’t want to release all the detected frequency after the Lock time.
Manual: Enable the Frequency, Bandwidth and Gain fader to be used manually. This will disable
the automatic detection.
Frequency/Bandwidth/Gain: The Frequency/Bandwidth/attenuation of notch filter for attenuating
the feedback.
Lock: Display if the feedback killers channel has detected and erased the frequency which are
causing the feedback.
Frequency/Bandwidth/Gain Level: Automatically display the locked frequency/bandwidth of the
notch filter/attenuation of frequency.
Manual All: Activate the manual settings with frequency, bandwidth and gain knobs.
Lock Time: The interval time to lock the detected feedback frequency, then the Feedback filter
will activate. If the Hold Button is enable, the detected feedback frequency will not disappear
after the Lock Time.
If the feedback appears randomly for a short time, it's better to set a appropriate 'Lock time'.
Stop Detect: Stop detecting feedback.
Reset All: Reset all the values.
Detect Level (dB): The target level which will consider as the Feedback source.