IDA8 Global-Net User Manual
496
© 2017, ATEÏS, member of PAX ProAV Group
Paging Event:
Binds a paging event for the zone selection.
Only events with a singular type are selectable.
See the section "Zone and Priority" below for
more details about the paging events.
Activation Mode:
o
None: If you want to paging using the control
console like PPM-AS or PSS-AS, which the
paging request is not coming from
component itself.
o
Permanent: The paging source is always
requested for paging such as background
music.
depending on the logic signal(Low to High
or High to Low) of an input.
The settings allow you to put multiple
channels to perform a logic operation
AND/OR to determine
the
paging
activities.
o
Modu Logic Signal: Under this mode,
IDA8 decides to request a paging if both the
modulation and logic signal conditions are
satisfied. It releases a paging request if one of
the conditions is achieved.
Zone and Priority
This section is about the zone section of a
paging request, and to specify the priority for
judgment if there are zones conflict with
another paging source which occupies it.
There are two types of paging events,
Integration and Singular.
Integration
An Integration paging event has multiple codes for
zone selection. This is for each code which is able to
assign the key of control consoles such as PPM-AS
and PSS-AS.
Click [....] button on Show grid, a setting window will
be displayed as the picture below.
Setting
Code: A zone combination or a selection of
zone. See the example above, the zone
combination of code is (Z1, Z2, and Z3)
which means zone 1, 2 and 3 will be
selected when requesting to paging.
All(Source/Priority): Select all the zones.
Zone Selection: Tick the checkbox to set a
zone in a code.
Priority: A priority value per zone along with
the code. If more than one source is
attempting to paging to the same zone,
IDA8 will decide which source for paging
by priority value.
Priority Visible: A checkbox to show/hide
the priority setting inside the grid.