IDA8 Global-Net User Manual
64
© 2017, ATEÏS, member of PAX ProAV Group
3.1.6.5
3rd Party Control
The following table lists the 3rd Party Control protocols supported by IDA8SAB-SW.
Protocol
Interface
Function
Connection
Settings
Ateis 3rd Party
Protocol
Ethernet(UDP)
UDP Port = 19761
Read/Write value of parameters.
Stepped adjustment for parameters.
Modbus
PDC(RS485)
PDC Port 1~ 2
Level control
Paging
Read Monitoring Status
Read Evacuation Status
Play Message
Logic I/O Control
3.1.7
Network Wiring
One IDA8C unit (Matrix Mode and
Switch Mode) and a IDA8SAB unit
(Matrix Mode and Switch Mode)
connect via Local Ateis Net.
Connection exam ple : Local Ateis Net.
One IDA8C unit (Matrix Mode and
Switch Mode) and 2 IDA8SAB
units (Matrix Mode and Switch
Mode) connect via Local Ateis
Net:
Inside the IDA8 units, the packets
travel around from A to B and B to
A through wires.
Therefore, the second slave unit is
the one connected to the IDA8C's
B port of Local Net.
Connection exam ple : Local Ateis Net.
Two IDA8C master-slave systems
connect with each other via
Global Ateis Net.
Connection exam ple : Global / Local Ateis Net.