IDA8 Global-Net User Manual
40
© 2017, ATEÏS, member of PAX ProAV Group
24V DC Input:
Main 24VDC power supply connector.
AC Power Socket:
Main 110~240 V 1.2A, 47~63Hz AC power input with fuse. If 24V DC and AC power are input at
the same time, IDA8C will use AC power, and switch to DC power if there is no AC power input.
Fuse Rating: 1.6A
3.1.2.3
Peripherals
The following table list the peripherals supported by IDA8SAB.
Device
Connection Max. Num
Function
PPM-AS
PDC
32
Remote console with paging ability.
PSS-AS
PDC
1
Remote console for Paging and Event Triggering(Element
Control, Master/Sub Preset Control).
URC-150AS
PDC
32
Remote console for Master/Sub Preset Controlling and Element
Controlling.
URGP32I
PDC
1
Evacuation Input extension.
URGP16I16O
PDC
1
Evacuation Input & output extension
DNM
PDC
16
Auto noise gain for audio signals
ANM
Analog
Audio
1
Detect Background Noise
CD8
PDC
1
Wall mounted cabinet remote paging console with 8 buttons/
zones.
CD16
PDC
1
Wall mounted cabinet remote paging console with 16 buttons/
zones.
CD Touch
PDC
1
Wall mounted cabinet remote paging console with touch screen
and Fireman Microphone.
PCP
PDC
32
Wall mounted cabinet remote paging console with telephone
styled microphone.
CDPM
PDC
1
Wall mounted cabinet remote paging console with 24 buttons/
zones and 2 extra selectable microphone sources.
PSC
PDC
32
A grouped console is comprised of a pad with a monitoring
speaker, a pad with a gooseneck and 8 buttons/zones, and two
pads with 8 buttons/zones.
DialPad
PDC
1
A remote dialer for making telephone calls via IDA8's telephone
hardware.
Wireless
Transceiver
PDC
1
An RF transceiver to communication between DialPad and IDA8,
DialPad can work without a physical connection.
Max. Number: The max. number of peripherals through per PDC port by using a Junction Box. For
example: On the PDC port, you can connect 32 PPM-AS through junction boxes and are able to
assign IDs in sequence for each unit in Ateis Studio.
Eth. Limit: The maximum number of IP that can be assigned over the network.
3.1.2.4
3rd Party Control
The following table lists the 3rd Party Control protocols supported by IDA8SAB.
Protocol
Interface
Function
Connection
Settings
Ateis 3rd Party
Protocol
Ethernet(UDP)
UDP Port = 19761
Read/Write value of parameters.
Stepped adjustment for parameters.
Modbus
PDC(RS485)
PDC Port 1~ 2
Level control
Paging
Read Monitoring Status
Read Evacuation Status
Play Message
Logic I/O Control