IDA8 Global-Net User Manual
110
© 2017, ATEÏS, member of PAX ProAV Group
configuration(IDA8C/S, amplifiers, wiring) should be completed before getting the reference.
Get All Reference:
Click the button to get the reference of gain value from the selected IDA8 processor.
Global Get Reference:
Click the button to get all the reference of gain value from all the IDA8 processors.
Reset All Reference:
Click the button to reset the reference of gain value from the selected IDA8 processor.
Reset Reference:
Clear the reference values of the selected zone to initialize the status. If the reference value is
cleared, the monitoring will stop.
Global Reset Reference:
Click the button to reset all the reference of gain value from all the IDA8 processors.
Reset Monitoring:
Click to reset all the monitoring on all the zones, and the detected faults from amplifier will be
cleared. After that, the monitoring function will execute the monitoring again.
Global Reset Monitoring:
Click the button to reset the monitoring function on all the IDA8 processors.
Measurement:
After completed the parameter settings at the lower part of [Normal Amplifier Settings] page, the
IDA8C/S starts to measure the value received from the internal circuit, and displays it on the grid at
the upper part of window.
Unloaded Reference:
Display the value of an unloaded reference which is the gain of an amplifier when there is no
load to the zone. This value is used to determine if there is a fault of a normal amplifier.
Full Loaded Reference:
Display the value of a full loaded reference which is the gain of an amplifier when there is a full